PowerFlex Digital DC Drive User Manual -
Publication 20P-UM001C-EN-P - July 2008
A-6
Supplemental Drive Information
Figure A.2 Logic Status Word
Logic Bits
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Status
Description
x Ready
0 = Not Ready
1 = Ready
x
Active
0 = Not Active
1 = Active
x
Command
Direction
0 = Reverse
1 = Forward
x
Actual
Direction
0 = Reverse
1 = Forward
x
Accel
0 = Not Accelerating
1 = Accelerating
x
Decel
0 = Not Decelerating
1 = Decelerating
x
Alarm
0 = No Alarm
1 = Alarm
x
Fault
0 = No Fault
1 = Fault
x
At Speed
0 = Not At Reference
1 = At Reference
x
x
x
Local
Control
(1)
(1)
for further information.
000 = Port 0 (TB)
001 = Port 1
010 = Port 2
011 = Port 3
100 = Port 4
101 = Port 5
110 = Reserved
111 = No Local
x
x
x
x
Reference
Source
0000 = Spd Ref A Auto
0001 = Spd Ref B Auto
0010 = Preset Spd 2 Auto
0011 = Preset Spd 3 Auto
0100 = Preset Spd 4 Auto
0101 = Preset Spd 5 Auto
0110 = Preset Spd 6 Auto
0111 = Preset Spd 7 Auto
1000 = Term Blk Manual
1001 = DPI 1 Manual
1010 = DPI 2 Manual
1011 = DPI 3 Manual
1100 = DPI 4 Manual
1101 = DPI 5 Manual
1110 = Reserved
1111 = Jog Ref