Table A.D Recommended Armature DC Output Fuses - 460V AC Input Frame A and B
(Regenerative Drives Only)
Table A.E Recommended Field Circuit Fuses - 230V AC Input Frame A and B
(Regenerative and Non-Regenerative Drives)
Frame
Drive
Current
Rating
Code
DC
Amps
AC
Line
Amps
Fuse Code FS2
(1)
Bussmann
Ferraz Shawmut (Gould Shawmut)
Ferrule FWP
Type
Ferrule
Fuse Block
North American
FWP Type
North
American
Fuse Block
Ferrule
A70QS Type
North American
A70P / A70QS Type
A 4P1
4.1
3.3
FWP-10A14F
CH142D
FWP-10B
–
A70QS10-14F A70P10-4
6P0
6
4.9
FWP-15A14F
FWP-15B
–
A70QS16-14F A70P15-4
010
10
8.2
FWP-20A14F
FWP-20B
–
A70QS20-14F A70P20-4
014
14
11.4
FWP-30A14F
FWP-30B
–
A70QS32-14F A70P30-4
019
19
15.5
FWP-40A14F
FWP-40B
–
A70QS40-14F A70QS40-4
027
37
22.1
FWP-63A22F
CH222D
FWP-60B
–
A70QS63-22F A70QS60-4
035
35
28.6
FWP-80A22F
FWP-70B
–
A70QS80-22F A70QS70-4
045
45
36.8
FWP-100A22F
FWP-90B
–
–
A70QS90-4
052
52
42.5
FWP-100A22F
FWP-100B
–
–
A70QS100-4
073
73
59.6
–
–
FWP-150A
ST14
–
A70QS150-4K
086
86
70.3
–
–
FWP-175A
–
A70QS175-4K
100
100
81.7
–
–
FWP-200A
–
A70QS200-4K
129
129
105.4 –
–
FWP-250A
–
A70QS250-4
B 167
167
136.4 –
–
FWP-350A
–
A70QS350-4
207
207
169.1 –
–
FWP-400A
–
A70QS400-4
250
250
204.3 –
–
FWP-500A
ST38-72612
–
A70QS500-4K
330
330
269.6 –
–
FWP-700A
–
A70QS700-4
412
412
336.6 –
–
FWP-800A
–
A70QS800-4
(1)
Required on four quadrant drives only, highly recommended on two quadrant drives.
Frame
Drive
Current
Rating
Code
Field
Amps Type
Fuse Code FS3
(1)
and
for location)
(1)
Internal fuses - provided with the drive.
Bussmann
Ferraz Shawmut
(Gould Shawmut)
SIBA
A
7P0
10
6 x 32 mm
FWH-016A6F
E085449
70 125 40.16
9P0
012
020
029
038
055
073
14
093
110
B
146
20
10 x 38 mm FWC-25A10F
A60Q25-2
60 033 05.25
180
218
265
360
434