PowerFlex Digital DC Drive User Manual -
Publication 20P-UM001C-EN-P - July 2008
3-32
Programming and Parameters
D
Y
N
A
MIC CO
NTR
O
L
Stop Mode
s
1262 [Closing Speed]
Motor speed at which the brake is closed. Used with External Brake
Control.
Default:
Min/Max:
Units:
30
0 / 200
RPM
1263 [Opening Delay]
Amount of time before the brake will open after the drive has been
enabled. Used with External Brake Control.
Default:
Min/Max:
Units:
0
0 / 30000
ms
1265 [Ramp In Zero En]
Enables/Disables the setting of the ramp input to zero. Used with
External Brake Control.
Default:
Options:
0 =
0 =
1 =
“Disabled”
“Disabled”
“Enabled”
1266 [Actuator Delay]
Amount of time before the actuator releases the load. Used with
External Brake Control.
Default:
Min/Max:
Units:
0
0 / 30000
ms
Restar
t Modes
1344 [Start At Powerup]
Enables/Disables the ability to issue a “Run” command and
automatically resume running at commanded speed after drive input
power is restored and the time in Par 1345 [Powerup Delay] has
elapsed. Requires a digital input configured for “Run” and a valid start
condition.
Default:
Options:
0 =
0 =
1 =
“Disabled”
“Disabled”
“Enabled”
1345
1345 [Powerup Delay]
Defines the programmed delay time, in seconds, before a start
command is accepted after a power up. If a “Start”, “Run” or “Stop”
command is asserted before the time in this parameter expires, the
“Start At Powerup” function will be aborted.
Default:
Min/Max:
Units:
1
1 / 10800
s
1344
Adaptv Regul
ator
181
[Adaptive Spd En]
Enables/Disables adaptive speed regulation.
The adaptive speed regulator function enables different gains of the
speed regulator depending on the speed or another variable (Par 183
[Adaptive Ref]). This allows optimum adaptation of the speed
regulator to your specific application. When adaptive speed regulation
is disabled, the regulator operates based on the settings in the
individual regulation parameters.
Default:
Options:
0 =
0 =
1 =
“Disabled”
“Disabled”
“Enabled”
182,
183
182
[Adaptive Reg Typ]
Selects the type of regulation used.
•
“Speed” = The regulator parameters follow a speed reference.
•
“Adaptive Ref” = The regulator parameters follow the reference
produced by Par 183 [Adaptive Ref].
Default:
Options:
0 =
0 =
1 =
“Speed”
“Speed”
“Adaptive Ref”
183
183
[Adaptive Ref]
The variable reference that the speed regulator parameter will follow
when Par 182 [Adaptive Reg Typ] = 1 “Adaptive Ref”.
Default:
Min/Max:
Units:
1000
–32768/+32767
RPM
182
184
[Adaptive Spd 1]
A percentage of Par 45 [Max Ref Speed] or the maximum value of Par
183 [Adaptive Ref].
Parameter set 1 is valid below the value set in this parameter and
parameter set 2 is valid above the value set in this parameter. The
transition between the values is defined by Par 186 [Adaptive Joint 1].
Default:
Min/Max:
Units:
20.34
0.00 / 200.00
%
183,
186
185
[Adaptive Spd 2]
A percentage of Par 45 [Max Ref Speed] or the maximum value of Par
183 [Adaptive Ref].
Parameter set 2 is valid below the value set in this parameter and
parameter set 3 is valid above the value set in this parameter. The
transition between the values is defined by Par 187 [Adaptive Joint 2].
Default:
Min/Max:
Units:
40.69
0.00 / 200.00
%
183,
187
File
Gr
oup
No.
Parameter Name & Description
See
page 3-2
for symbol descriptions
Values
Related
A
A
A
A
!
ATTENTION: Equipment damage and/or personal injury may result if this parameter is used in
an inappropriate application. Do not use this function without considering applicable local,
national and international codes, standards, regulations or industry guidelines.