Installing Control Wiring
7-11
7.7.3 Changing Reference Sources
The selection of the active Speed Reference can be made through
digital inputs, DPI command, Jog key, or Auto/Manual OIM
operation. See figures 7.3 and 7.4.
7.7.4 Auto/Manual Control
The Auto/Manual input is not part of the logic commands controlled
by parameter 89 (Logic Source Sel). The Auto/Manual input affects
the speed reference source only.
In Auto reference mode, the reference source is determined by
terminal block inputs (if configured) or a parameter (Speed Ref A
Sel). Only one port at a time can control (own) the reference source.
In Manual reference mode, the reference source for the drive is
based on the port that commanded it most recently. The last source
that commands Manual reference mode will determine the
reference used by the drive.
The Auto/Manual function is available through the terminal block
(edge sensitive) and LCD OIM function keys. If configured on the
terminal block, it is possible to have the digital input in the "Manual"
position but have the Manual reference being controlled from
another port. Because it is an edge-sensitive signal, the digital input
would have to be switched to "Auto" and then back to "Manual" to
re-acquire Manual reference control.
The Jog reference will bypass the Auto/Manual reference while it is
asserted from the control source. When the Jog reference is
released, the control source reverts to source that was in effect
before the Jog reference was asserted.
Figure 7.3 – Speed Reference Control Flowchart
Preset Speed 1, Parameter 101
Preset Speed 2, Parameter 102
Preset Speed 3, Parameter 103
Preset Speed 4, Parameter 104
Preset Speed 5, Parameter 105
Preset Speed 6, Parameter 106
Preset Speed 7, Parameter 107
TB Man Ref Sel, Parameter 096
Auto/Manual
Digital Input
DPI Port Ref 1-6, See Parameter 209
DPI Command
Jog Speed, Parameter 100
Jog Command
Trim
[Digital Inx Select]:
Speed Sel 3 2 1
0 0 1
0 1 1
0 1 0
1 0 0
1 0 1
1 1 0
1 1 1
Auto
Man
Drive Ref Rslt (272)
Commanded
Frequency (2)
Min/Max Speed
Acc/Dec Ramp
and
S Curve
Pure Reference
Post Ramp Reference (273)
to follower drive for
Frequency Reference
to follower drive for
Frequency Reference
Auto Speed Ref Options
Manual Speed Ref Options
Slip Compensation (123)
1 "Slip Comp"
None
0 "Open Loop"
PI Output (138)
2 "Process Pi"
Speed Adders
[Speed Mode]:
PI Exclusive Mode
[PI Configuration]:
Bit 0, Excl Mode = 0
Output
Frequency (1)
Mod Functions
(Skip, Clamp,
Direction, etc.)
Speed Ref A Sel, Parameter 090
0 0 0
StockCheck.com
Downloaded from StockCheck.com
Summary of Contents for Reliance electric 6SB401 Series
Page 10: ...VIII SP600 AC Drive User Manual S t o c k C h e c k c o m Downloaded from StockCheck com ...
Page 14: ...1 2 SP600 AC Drive User Manual S t o c k C h e c k c o m Downloaded from StockCheck com ...
Page 48: ...Mounting the Drive 3 12 S t o c k C h e c k c o m Downloaded from StockCheck com ...
Page 86: ...Installing Control Wiring 7 14 S t o c k C h e c k c o m Downloaded from StockCheck com ...
Page 102: ...10 8 SP600 AC Drive User Manual S t o c k C h e c k c o m Downloaded from StockCheck com ...
Page 232: ...Technical Specifications A 8 S t o c k C h e c k c o m Downloaded from StockCheck com ...
Page 248: ...B 16 SP600 AC Drive User Manual S t o c k C h e c k c o m Downloaded from StockCheck com ...
Page 256: ...C 8 SP600 AC Drive User Manual S t o c k C h e c k c o m Downloaded from StockCheck com ...
Page 258: ...D 2 SP600 AC Drive User Manual S t o c k C h e c k c o m Downloaded from StockCheck com ...
Page 260: ...E 2 SP600 AC Drive User Manual S t o c k C h e c k c o m Downloaded from StockCheck com ...
Page 266: ...F 6 SP600 AC Drive User Manual S t o c k C h e c k c o m Downloaded from StockCheck com ...
Page 273: ...S t o c k C h e c k c o m Downloaded from StockCheck com ...