9-8
SP600 AC Drive User Manual
To restore all parameters to their factory-default values, select
Reset Defaults from the Memory Storage menu.
To see which parameters have been adjusted from their default
values, select Changed Params from the Parameters menu. This
procedure is described in section 13.8.4 of this manual.
Note that parameter values are retained through a line dip or power
shutdown.
9.7.2
Loading and Saving User Sets
Up to three drive configurations, called user sets, can be saved and
recalled for use at any time in the SP600 drive. When the drive is
shipped from the factory, all user sets have the same factory default
values. Resetting the drive parameters to their default values does
not affect the contents of the user sets.
Saving a User Set
A user set can only be saved when the dynamic user set configure
parameter (204) is programmed to “disable.” Please refer to section
2.4.19 for more information. To save the current drive configuration,
select Save to User Set from the Memory Storage menu. Then
select user set 1, 2, or 3 as the area in which to store data. See
figure 9.6.
Table 9.2 – How to Adjust Each Parameter Type
Parameter
Type
How to Adjust
Numbered List
Use
to advance through the list of options.
Bit
Use
to move the cursor to the bit location you
want to change. Use
to change the value of the
bit.
Numeric
Use
to increase or decrease the value.
- Or -
Use
to move the cursor from digit to digit, and
use
to increase or decrease the value of the
digit.
Figure 9.6 – Save to User Set
MEMORY
User Set 1
User Set 2
User Set 3
Summary of Contents for Reliance electric 6SP201-015
Page 14: ...1 2 SP600 AC Drive User Manual ...
Page 54: ...Mounting the Drive 3 16 ...
Page 82: ...6 12 SP600 AC Drive User Manual ...
Page 96: ...7 14 SP600 AC Drive User Manual ...
Page 232: ...Parameter Descriptions 12 102 ...
Page 280: ...B 8 SP600 AC Drive User Manual ...
Page 282: ...C 2 SP600 AC Drive User Manual ...
Page 284: ...D 2 SP600 AC Drive User Manual ...
Page 298: ......
Page 299: ......