12-6
SP600 AC Drive User Manual
Displays the output voltage present at terminals T1, T2, and T3 (U,
V, and W).
Displays the output power present at T1, T2, and T3 (U, V, and W).
Displays the output power factor.
Displays the accumulated output energy of the drive.
Displays the accumulated time the drive has been outputting power.
6
Output Voltage
Range:
0.0 to Drive Rated Volts [0.1 VAC]
Default:
Read Only
Access:
0
Path: Monitor>Metering
See also:
7
Output Power
Range:
0.0 to Drive Rated kW x 2 [0.1 kW]
Default:
Read Only
Access:
0
Path: Monitor>Metering
See also:
8
Output Powr Fctr
Range:
0.00 to 1.00 [0.01]
Default:
Read Only
Access:
2
Path: Monitor>Metering
See also:
9
Elapsed MWh
Range:
0.0 to 429,496,729.5 MWh [0.1 MWh]
Default:
Read Only
Access:
2
Path: Monitor>Metering
See also:
32
10
Elapsed Run Time
Range:
0.0 to 429,496,729.5 Hr [0.1 Hr]
Default:
Read Only
Access:
1
Path: Monitor>Metering
See also:
32