Parameter Descriptions
12-83
Sets the highest input value to the analog input 2 scaling block. See
an example of Analog Input #1 scaling in parameter 322.
Sets the lowest input value to the analog input 2 scaling block.
325
Analog In 2 Hi
Range:
4.000 to 20.000 mA [0.001 mA]
-/+10.0 V [0.1 V]
0.0 to 10.0 V [0.1 V]
Default:
10 V
Access:
2
Path: Inputs & Outputs>Analog Inputs
See also:
91, 92
326
Analog In 2 Lo
Range:
4.000 to 20.000 mA [0.001 mA]
-/+10.0 V [0.1 V]
0.0 to 10.0 V [0.1 V]
Default:
0.000 V
Access:
2
Path: Inputs & Outputs>Analog Inputs
See also:
91, 92