Wiring Requirements for the Drive
4-3
4.1.1 Power Wire Sizes
Input power wiring should be sized according to applicable codes to
handle the drive’s continuous-rated input current. Output wiring
should be sized according to applicable codes to handle the drive’s
continuous-rated output current. See table 4.2 for the range of
power wire sizes that the terminals can accommodate.
Table 4.1 – Recommended Shielded Wire
Location
Rating/Type
Description
Standard
(Option 1)
600V, 90°C (194°F)
XHHW2/RHW-2
Anixter
B209500-B209507,
Belden 29501-29507,
or equivalent
• Four tinned copper conductors with XLPE insulation.
• Copper braid/aluminum foil combination shield and
tinned copper drain wire.
• PVC jacket.
Standard
(Option 2)
Tray rated 600V, 90° C
(194° F) RHH/RHW-2
Anixter OLF-7xxxxx or
equivalent
• Three tinned copper conductors with XLPE
insulation.
• 5 mil single helical copper tape (25% overlap min.)
with three bare copper grounds in contact with
shield.
• PVC jacket.
Class I & II;
Division I & II
Tray rated 600V, 90° C
(194° F) RHH/RHW-2
Anixter 7V-7xxxx-3G
or equivalent
• Three bare copper conductors with XLPE insulation
and impervious corrugated continuously welded
aluminum armor.
• Black sunlight-resistant PVC jacket overall.
• Three copper grounds on #10 AWG and smaller.
Table 4.2 – Power Terminal Block Specifications
Name
Description
Frame
Wire Size Range
1
1
Maximum/minimum sizes that the terminal block will accept. These are
not recommendations.
Torque
Max
Min
Power
Terminal Block
Input power
and motor
connections
A, B & C 3.5 mm
2
(12 AWG)
0.3 mm
2
(22 AWG)
0.6 N-m
(5 in-lb)
D
8.4 mm
2
(8 AWG)
0.8 mm
2
(18 AWG)
1.4 N-m
(12 in-lb)
E
25.0 mm
2
3 AWG)
2.5 mm
2
(14 AWG)
2.71 N-m
(24 in-lb)
SHLD
Terminal
Terminating
point for
wiring shields
All
---
---
1.6 N-m
(14 in-lb)
Summary of Contents for Reliance electric 6SP201-015
Page 14: ...1 2 SP600 AC Drive User Manual ...
Page 54: ...Mounting the Drive 3 16 ...
Page 82: ...6 12 SP600 AC Drive User Manual ...
Page 96: ...7 14 SP600 AC Drive User Manual ...
Page 232: ...Parameter Descriptions 12 102 ...
Page 280: ...B 8 SP600 AC Drive User Manual ...
Page 282: ...C 2 SP600 AC Drive User Manual ...
Page 284: ...D 2 SP600 AC Drive User Manual ...
Page 298: ......
Page 299: ......