Specifications
Max.
Armature
HP Range HP Range
Current
with115 VAC
with 230 VAC
Model
(Amps DC)
Applied
Applied
DC3N-12D-00-010-AI
10A
1/4 – 1
1/2 – 2
DC3N-12D-4X-010-AI
10A
1/4 – 1
1/2 – 2
Model
Style
DC3N-12D-00-010-AI
Open chassis
DC3N-12D-4X-010-AI
NEMA 4X/12
AC Line Voltage
115 VAC or 230 V AC, 50 or 60 Hz, 1 Phase
Maximum Allowable Symmetrical AC Line Current
5000 amps
Maximum AC Line Distribution kVA
with 115 VAC Input
25 kVA
with 230 VAC Input
50 kVA
Armature Voltage
With 115 VAC Input
0 – 90 VDC
With 230 VAC Input
0 – 180 VDC
Field Voltage
115 VAC Input
50 VDC (F1 to L1); 100 VDC (F1 to F2)
230 VAC Input
100 VDC (F1 to L1); 200 VDC (F1 to F2)
Maximum Field Current
1 ADC
Adjustments and Application Data
Form Factor
1.37 at base speed
Service Factor
1
Maximum Speed Trimpot Range (% of rated input voltage)
0 to 90%
1
Summary of Contents for RELIANCE ELECTRIC DC3N Series
Page 83: ...75 Troubleshooting Figure 20 DC3N Block Diagram Block Diagram ...
Page 90: ...NOTES 82 ...