ADJUSTMENTS & SET UP 

UNITS A & B 

 

        

 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 

Model - FC-200-2 

P/N 121-000-2001 

 

 

 

 
 

 

 

Listed, File No. 

E183233

 

 

Input:

 

120 VAC, 50/60 HZ.

 

 

Double Unit Fuse Sizes:  

Unit A = 10 & Unit B = 5 AMPS

 

Output: 0-120 VAC 

80% Duty Cycle at Rated AMPS  

© 2009 RODIX

 

INC

.

 
 
 

 

ELECTRICAL CONNECTIONS: 

Make the electrical connections prior to plugging the 
control in and turning it on.  Once connections are 
made to the feeder control, any desired software 
settings changes can be made with the cover closed. 

 

1.  PART SENSOR

 

(Photo-sensor or Proximity Switch) 

Connect a three wire, current-sinking (NPN) or current-
sourcing (PNP) sensor as shown on the enclosed 
wiring diagram.  The sensor must be able to operate 
on 12VDC and switch 3mA.  The default setting is a 
universal sensor input. 

 

2.  RUN JUMPER INPUT

 

A Run Jumper is factory installed as shown on the 
enclosed wiring diagram.   

 

If the Feeder Cube

 is to be controlled by a relay 

contact, switch or other device, replace the factory-
installed jumper with the controlling "Run Contact" at 
terminals 8 and 9 of TB2 (small terminal strip).  The 
contact must be able to switch 12VDC and 1.0 mA.  
The control will then run only when the contact is 
closed and the part sensor is calling for parts. 

 

In the High/Low parts sensing mode, a second parts 
sensor can be connected to the run contact input in 
place of the run jumper.  The parts sensor should be a 
PNP type and have the same logic (L.O. or D.O.). 

 

 

3.  AUXILIARY OUTPUT 

The Feeder Bowl/Hopper Interlock feature (TB2-2 & 3 ) 
can be connected to a Rodix FC-40, FC-90 or FC-200 
Series control when control of a bulk material hopper is 
needed.  The interlock will prevent the hopper from 
operating anytime the bowl is turned OFF or in 
"STAND BY" mode.  The Interlock output is capable of 
12 VDC at 50 mA.  The Aux output is capable of 
switching 100 mA at 12 or 24VDC if an external power 
supply is used. For further information download (or 
request from RODIX) the FC-200 Series Advanced 
Features Application Note.  The Interlock output can 
be used to drive a solid state relay that can operate 
auxiliary equipment such as an air valve.  Two FC-200 

Series controls can be interlocked. Download the 
FC-200-2 Application Note for wiring information. 

 

A 0.6 Watt 12VDC solenoid can be driven by the 
Aux output.  Note: a diode must be placed across 
the solenoid in reverse polarity to adsorb the 
energy when the solenoid is de-energized.  Failure 
to do so voids the warranty.  See the wiring 
diagram for proper connections. 

 

  4.  LINE VOLTAGE CONNECTIONS

 

The 120VAC models can operate from a power 
line providing from 108 to 132VAC.   The plug can 
be connected to a standard North American outlet. 
The outlet should be properly grounded. The 
240VAC models can operate from 200 to 265VAC. 
The control should be grounded properly. 
 

5.  INTERNAL POWER SUPPLY 

At the rated line voltage, the line isolated power 
supply is capable of providing a combined total 
current of 65 mA at 12 VDC (35 mA when using a 
200VAC line on 240VAC models).  The total 
current includes the parts sensor, CFR sensor and 
any auxiliary output accessories that are 
connected to the Bowl/Hopper Interlock terminals. 

 

 

6.  OUTPUT CONNECTIONS

 

The 120VAC models in a general purpose 
enclosure provide a standard North American 
outlet for connection to the feeder.  

 

7. EXTERNAL SPEED CONTROL 

CONNECTIONS

 

The following methods of remote power level 
control can be utilized when desired:  

A.  The Constant Feed Rate (CFR) feature: Attach 

a CFR sensor to terminals TB2-12 (blue) and to 
TB2-9 (brown).   

B.  4-20mA or 0-20mA signal can be connected by 

bringing the positive signal wire to TB2-12 and 
ground to TB2-11. 

 

C.  0-5VDC Analog input signal can be connected 

to connector H1.  This can be selected to 
ignore any connections to the CFR/4-20mA 
input.  Control cable 123-145 sold separately. 

 Section 13 explains how to enable these features. 

 

FC-200-2.doc 11/16/2009  Page 1

Summary of Contents for FEEDER CUBE FC-200-2

Page 1: ...ply is used For further information download or request from RODIX the FC 200 Series Advanced Features Application Note The Interlock output can be used to drive a solid state relay that can operate auxiliary equipment such as an air valve Two FC 200 Series controls can be interlocked Download the FC 200 2 Application Note for wiring information A 0 6 Watt 12VDC solenoid can be driven by the Aux o...

Page 2: ... output of the feeder B The auxiliary output signal can be inverted from the output of the feeder Set the Aux Out parameter to Invert to activate it C The auxiliary output signal can be set as an alarm to indicate when the bowl out of parts timer has stopped the feeding of the bowl Set the Aux Out parameter to Alarm to activate it D The auxiliary output signal can be set to invert the alarm when t...

Page 3: ...rs to adjust the amplitude through the normal operating display All other settings can only be adjusted after entering the security code C The Lock setting locks the control from any adjustment without the use of the security code If the security code has been forgotten press the enter key to bring up the security code Next push and hold the back key until the menu appears This sequence bypasses t...

Page 4: ...ing area before applying the adhesive backed mount E CONNECT THE SENSOR to the control The sensor s brown wire connects to 12VDC at TB2 9 The blue wire connects to the signal input at TB2 12 F Section 13 explains how to enable the CFR feature WARNING Fuses should be replaced with Bussman ABC or Littelfuse 3AB Fast Acting type or equivalent of manufacturer s original value Mounting this control on ...

Page 5: ...B1 OPTICS POWER TB1 GND Bl 14 Or 14 Bl 14 Bl 14 Wh 14 Wh 20 Vi 20 S Wh 14 PNP NPN RUN Optional 0 5VDC Input H3 H4 A2 Gate A1 TRANSFORMER TRIAC UNIT A UNIT B 1 H1 Keypad P1 SMALL TB2 AUX FEATURE TERM STRIP RUN JUMPER AUX CFR SENSOR Option 123 170 Bu Br 1 11 2 11 4 5 12 9 10 3 8 3 7 SIG 2 5 9 1 6 LOA D 10 ACCEPTS BOTH OPTIC AND PROX SENSORS NPN OR PNP LINE VOLTAGE P N 111 500 Yl 20 COM CONNECT SINK ...

Page 6: ... Defaults restores as it came from the factory bold text Language Select Language English Spanish French German select desired language Normal Display Message Priority The normal operating display shows the status of the control with regard to input signals and control settings They are listed from highest to lowest in priority The highest priority message takes precedence over all other messages ...

Page 7: ...ons for Electrical Noise 1 Use shielded wires for all I O Input Output signals The I O signals may include 4 20mA input Run input Sensor input 0 5VDC input Interlock input or AUX output The shield drain wire should be tied to the chassis in the Rodix control The drain wire should be kept shorter than 2 Please see the enclosed picture Example of a drain wire termination 2 Never run I O signal wires...

Reviews: