6. FEATURE PROGRAMMING CHART
“
X
” means the setting could be in either position
because the position doesn’t matter.
“
0
” means the “resistor” jumper has been removed.
7. LOW VOLTAGE AT “1”
Some small feeders may feed faster than desired at low
settings on the dial. The “Low Voltage at 1” program
allows the control’s output to operate at a much lower
minimum voltage than the standard minimum voltage.
To enable this feature break through resistor R25 with a
knife.
TROUBLESHOOTING
For the control to run: The
AMPLITUDE POT
must be
turned up and the RUN LED must be lit. To light the
RUN LED, connect a Run Jumper from TB2 terminal 3
to 4, or apply a 10-30 VDC signal at TB2 terminals 1 &
2. See the “FC-70 Troubleshooting Guide” for more
information. If the feeder only hums or barely moves
parts, toggle the 60/120 dip switch to match the feeder’s
tuning.
DIMENSIONS
WARNING:
Fuses should be replaced with a Bussman
ABC or Littelfuse 3AB "Fast Acting" type or
equivalent of manufacturer's original value.
Mounting this control on a vibrating surface
will void the warranty.
WARRANTY
Rodix Control Products are Warranted to be free
from defects in material and workmanship under
normal use for a period of two years from date of
shipment.
For the full description of the warranty,
terms, and software license, please contact the factory.
For assistance installing or operating your Rodix Feeder
Cube® please call the factory or visit our web site.
Technical help is available to answer your questions and
email any needed information. To return a control for IN
or OUT of warranty service, please ship it prepaid to:
Rodix Inc., ATTN: Repair Department
If under warranty, Rodix will repair or replace your
control at no charge; If out of warranty, we will repair it
and you will be billed for the repair charges (Time and
Material) plus the return freight. Quotes for repairs are
available upon request. A brief note describing the
symptoms helps our technicians address the issue.
Feeder Cube® is a registered TM of Rodix Inc.
RODIX, INC.
2316 23
rd
Ave., Rockford, IL 61104
Toll Free (800) 562-1868, FAX (815) 316-4701
E-mail custserve@rodix.com
www.rodix.com
FC-70-240 24-215.doc 4/8/2015 Page 2
Feature Programming Chart
Program Description
SW1 R24 R25
Standard Program
X
1
1
60 Pulse Reverse
60
0
X
40 Pulse Operation
120
0
X
Low Voltage at “1”
X
X
0