6  Package 

6.1  Flight Case 
6.1.1  Standard   

 

SAP:

 309003-00470 

Dimensions: 

1167 x 619 x 835 mm 

Capacity: 

Every flight case can carry 10 pcs tiles. 

 

 

Figure 6-1. DM2.6 Flight Case 

6.1.2  Optional 

 

SAP:

 309003-00390 

Dimensions: 

1167 x 619 x 835 mm 

Capacity: 

Every flight case can carry 8 pcs tiles. 

 

 

Figure 6-2. DM2.6 Flight Case 

Note: 

The left space in the middle of the flight case is designed for cables and / or accessories. 

1142

M

ax

 8

35

Max 1167

14

3

81

0

594

Max 619

Summary of Contents for Diamond 2.6

Page 1: ...Diamond 2 6 User Manual Version 2 3 Updated 2019 04 01 ...

Page 2: ...rates 4 The warranty will be voided in the case of a Accidents or human error b Any modifications disassembly repairs maintenance or testing unauthorized by ROE c The product series number is broken including SN ESN MEID IMEI d Gross negligence Contact Information If you have any questions about this document please feel free to contact with ROE technical service team ROE China ROE Visual Co Ltd N...

Page 3: ...ion Requirements 9 3 1 Mechanical Requirements 9 3 2 Electrical Requirements 9 3 3 System Requirements 9 4 Components 10 4 1 Overview 10 4 2 Module 11 4 3 Power Box 11 5 Accessories 12 5 1 For Hanging 12 5 2 For Stacking 13 5 3 A Complete Stacking System 14 5 4 Locking Plate Curving Plate 15 5 5 Cables 16 6 Package 18 6 1 Flight Case 18 7 Installation Overview 20 8 Quick start Guide 21 8 1 Hanging...

Page 4: ...rs 27 10 Control System 28 10 1 Processor Port Capacity 28 10 2 Tile Type 29 11 Service Manual 30 11 1 Cleaning Tiles 30 11 2 Installing Tiles 31 11 3 Replacing the Module 33 11 4 Tools Needed 34 11 5 Replacing the Power Unit 35 11 6 Replacing the Receiving Card 36 11 7 Replacing the Tile Handle 37 11 8 Replacing the Module Handle 37 ...

Page 5: ...WARNING Be careful of hazardous emission WARNING Mind your fingers when working with heavy loads WARNING Pay attention to the hot surface Installation Personnel The installation must be performed by authorized and qualified technical personnel only Product Care All components should be kept dry clean lubricated only of recommended coated properly and otherwise maintained in a manner consistent wit...

Page 6: ...u are thoroughly familiar with all safety guidelines instructions warnings and cautions Otherwise it may increase risks of hazards and injury to the user 5 Please install and or keep this product away from flammable materials heat sources water high power electrical devices and dangerous chemicals 6 Please use and or store this product in proper temperature and humidity 7 Please earth this product...

Page 7: ...solution for rental stage and fixed applications 2 1 1 Ultra lightweight The DM2 6 is 500 x 500 mm but its weigh less than 5 5kg per tile The lightweight magnesium alloy frame ensures the extreme durability 2 1 2 Superb Visual The sleek design with black LEDs highlights its high contrast and brightness for a vivid visual effect 2 1 3 Curving Options Concave and convex curving options enable you to...

Page 8: ...t to Output 16 bit Refresh Rate 1 920 HZ Scan 1 16 Viewing Angle Hor Vert 140 140 Dimensions W x H x D 500 x 500 x 81 mm 19 7 x 19 7 x 3 2 Frame Material Magnesium Alloy Weight Tile 5 5 kg Max Hanging 20 tiles Max Stacking 8 tiles Max Power Consumption 180W Curve Max Concave 10 Convex 5 IP Rate IP 40 Indoor only Lifetime 50 000 hours Control System Evision Brompton Operating Temperature 20 C to 45...

Page 9: ...les and frames on an inclined surface 3 1 3 Ballast In consideration of the expected wind load the height and position of the LED wall upon the stacking system the additional weight ballast should be required The detailed information how to calculate the ballast weight refers to Ballast Weight Calculation 3 2 Electrical Requirements 3 2 1 Power ROE tiles require 110 240 VAC 50 60 Hz and should be ...

Page 10: ... 04 Copyright 2019 ROE Visual Co Ltd All Rights Reserved 10 37 4 Components 4 1 Overview A DM2 6 tile consists of modules tile frame and power box Figure 4 1 DM2 6 Components Figure 4 2 DM2 6 Parts Information Module Magnet Tile Frame Power Box ...

Page 11: ... 04 04 Copyright 2019 ROE Visual Co Ltd All Rights Reserved 11 37 4 2 Module A DM2 6 tile consists of 4 pcs modules Dimensions 250 x 250 mm Figure 4 3 Module Dimensions 4 3 Power Box Dimensions 75 x 390 x 45 mm Figure 4 4 Power Box Dimensions ...

Page 12: ...nging Hanging Bar_Clamp_0 5m SAP 207002S0212 Weight 5 2 kg Dimensions 484 x 80 x60 mm Hanging Bar_Clamp_1 0m SAP 207002S0211 Weight 8 6 kg Dimensions 993 x 80 x 60mm Hanging Bar_Shackle_0 5m SAP 304010 00275 Weight 5 2 kg Dimensions 484 x 80 x60 mm Hanging Bar_Shackle_1 0m SAP 304010 00276 Weight 8 6 kg Dimensions 993 x 80 x 60mm ...

Page 13: ...mensions 493 x 80 x 110 Stacking Bar_1 0m SAP 304010 00277 Weight 8 3 kg Dimensions 993 x 80 x 110 mm Base Stablizer SAP 304012 01526 Weight 8 0 kg Dimensions 1040 5 x 293 x 90 mm Stacker SAP 304012 00504 Weight 4 65 kg Dimensions 1040 5 x 290 x 50 mm Rear Bridge SAP 206002S0178 Weight 1 02 kg Dimensions 232 x 106 5 x 35 mm Rear Bridge Adaptor SAP 304012 01857 Weight 0 4 kg ...

Page 14: ...019 04 04 Copyright 2019 ROE Visual Co Ltd All Rights Reserved 14 37 5 3 A Complete Stacking System Note The stacking system should be used every two tile wide at least and it s will be better to be used every one tile wide when necessary ...

Page 15: ...Plate SAP 304014 00009 Weight 240g Two way Curving Plate SAP 304012 01853 Weight 288g Four way Curving Plate SAP 304012 01852 Weight 376g Note The curving plate can achieve concave 15 and convex 10 but DM2 6 tiles can only achieve concave 10 and convex 5 5 4 2 How to Use the Locking Plate 5 4 3 How to Calculate How Many Locking Plates You Need Press the button to unlock and lock it The direction i...

Page 16: ...Weight 0 11 kg Neutrik_Neutrik Connectors Connect neighboring tiles vertical Power Cable_2 4m SAP 208001S1194 Weight 0 4 kg Neutrik_Neutrik Connectors Connect tiles in neighboring columns Main Data Cable_30m SAP 208004S0506 Weight 1 2 kg Neutri_Neutrik Connectors Connect the processor and tiles Data Cable_0 43m SAP 208004S0529 Weight 0 075 kg Neutri_Neutrik Connectors Connect neighboring tiles ver...

Page 17: ... 37 5 5 2 Power Cable Plug in the power cable turn the power cable clockwise until you feel a click Pull back the button on the plug turn the power cable anti clockwise and plug it out 5 5 3 Data Cable Plug in the data cable and you feel a click Press the button on the socket and plug the data cable out ...

Page 18: ...1167 x 619 x 835 mm Capacity Every flight case can carry 10 pcs tiles Figure 6 1 DM2 6 Flight Case 6 1 2 Optional SAP 309003 00390 Dimensions 1167 x 619 x 835 mm Capacity Every flight case can carry 8 pcs tiles Figure 6 2 DM2 6 Flight Case Note The left space in the middle of the flight case is designed for cables and or accessories 1142 Max 835 Max 1167 143 810 594 Max 619 ...

Page 19: ...oevisual com 2019 04 04 Copyright 2019 ROE Visual Co Ltd All Rights Reserved 19 37 6 1 3 Labels on the Flight Case Warning Indoor use Warning Keep the flight case upwards Warning Maximum stack 3 flight cases Warning Fragile 3 ...

Page 20: ... Rights Reserved 20 37 7 Installation Overview Figure 7 1 DM2 6 Cabling Video Source 2 Power Cable_0 43m_Neutrik_Neutrik 3 Main Data Cable_30m_Neutrik_Neutrik 4 Data Cable_0 43m_Neutrik_Neutrik AC AC AC AC AC AC 1 Main Power Cable_10m_Weipu_Neutrik Main Power Cable_10m_Neutrik_Neutrik ...

Page 21: ...king Take out DM2 6 tiles from flight cases 8 1 Hanging System 1 Fix the hanging bar on the truss close the G clamp and adjust the position of G clamps to avoid the truss 2 Fix more hanging bars and keep them at the same horizontal level through the adjustment wheel Note The adjusting range of the adjustment wheel is 13 9mm vertical and 157mm horizontal respectively ...

Page 22: ...hts Reserved 22 37 3 Install tiles on hanging bars Hanging bars will attract tiles to correct target position automatically with magnets 4 Before installing more panels fix hanging bars and tiles with locking plates 5 Before installing more tiles fix neighboring tiles with locking plates ...

Page 23: ...rding to the complete stacking system See 4 2 2 Install two tiles on the stacking bar which will attract tiles to the target position automatically with magnets And lock the rear bridge 3 Install the second stacking system close to the first stacking system and keep them at the same horizontal level through the adjustment wheel 4 Install tiles on the second stacking system and fix them with 4 way ...

Page 24: ...Co Ltd All Rights Reserved 24 37 5 Repeat Step 3 to 4 until installing all stacking systems and keep them at the same horizontal level through the adjustment wheel 6 Install more tiles and fix them with locking plates Note The adjusting range of the feet stacking bar is 48mm ...

Page 25: ...1113 1214 1315 1417 1518 8 133 265 397 529 661 793 925 1057 1189 1322 1454 1586 1718 1850 1982 W H 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 1 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 2 133 141 149 157 166 174 182 190 199 207 215 223 232 240 248 3 298 316 335 353 372 391 409 428 446 465 484 502 521 539 558 4 529 562 595 628 661 694 727 760 793 826 859 892 925 958 991 5 826 878 929 981 1033 ...

Page 26: ... to the power out port Connect the first power in port and power source with one 10m main power cable How to calculate the power cable capacity Formula Voltage Current Safety Factor 0 8 Power If the voltage is 220V one power cable can load 15 pcs DM2 6 tiles If the voltage is 110V one power cable can load 7 pcs DM2 6 tiles Note The number in cabling is in line with that of in cables See 4 3 Cables...

Page 27: ...th 0 4m data cables 9 3 Others Connect tiles with the processor through 30m data cables Connect the processor with a PC laptop via the Ethernet port Connect the video source Notes 1 The front view is for the setting in the control system 2 The cascade control data cables should not be more than 100 meters When it s over 100 meters please switch to fiber cables ...

Page 28: ...iles support both Brompton and Evision 10 1 Processor Port Capacity 10 1 1 Brompton Color Depth Frame Rate 8 bit 10 bit 12 bit 24 Hz 35 28 23 25 Hz 34 27 22 30 Hz 28 22 18 50 Hz 17 13 11 60 Hz 14 11 9 10 1 2 Evision Color Depth Frame Rate 8 bit 10 bit 12 bit 24 Hz 17 17 17 25 Hz 17 17 17 30 Hz 17 17 17 50 Hz 17 15 14 60 Hz 17 13 11 ...

Page 29: ... roevisual com 2019 04 04 Copyright 2019 ROE Visual Co Ltd All Rights Reserved 29 37 10 2 Tile Type 10 2 1 Brompton 10 2 2 Evision Note More information about Brompton Evision please refer to the control system user manual ...

Page 30: ... Tools Detergent Pow R Wash PR You can buy it from ROE or from the supplier https www chemtronics com pow r wash pr Dust free Cloth for LEDs 11 1 2 Steps Step 1 Spray a little detergent on the cloth and clean the tile gently Step 2 Spray more and keep cleaning until the tile is clean Note In terms of the cleaning frequency it depends on the actual situation ...

Page 31: ...9 04 04 Copyright 2019 ROE Visual Co Ltd All Rights Reserved 31 37 11 2 Installing Tiles In order to protect LEDs on tile edges from damage the tile frame should be attracted by magnets first then modules with LEDs mounted on 11 2 1 Hanging ...

Page 32: ...DM2 6 User Manual www roevisual com 2019 04 04 Copyright 2019 ROE Visual Co Ltd All Rights Reserved 32 37 11 2 2 Stacking ...

Page 33: ...ing the Module 11 3 1 Steps Step 1 Take down the defective module and unscrew the safety rope Note It s recommended to push out the module with your thumb at the top left of the module where the magnet locates Step 2 Take a new module install it and tighten the safety rope Note Please note the direction of the module ...

Page 34: ...nd tweezers Screw Size Location Screwdriver Set Head Size Twisting Force M3x8mm Power Unit Φ4 0 x 25 x 2 4 0 0 3 kg cm PM3x6mm Electric Coupler Φ4 0 x 25 x 2 4 0 0 3 kg cm CM2x10mm Hub Board Φ2 0 x 25 x 0 1 5 0 3 kg cm PWM2x4mm Receiving Card Φ2 0 x 25 x 0 1 5 0 3 kg cm PM5x26mm Tile Handle Φ4 0 x 25 x 2 5 0 0 3 kg cm PM4x8mm Module Handle Φ4 0 x 25 x 2 4 0 0 5 kg cm ...

Page 35: ...nd unscrew four M3x8mm screws two PM3x6mm and three terminals which are used to fix and connect the power unit Note It s recommended to take down the transparent cover over terminals by the tweezers Step 3 Take down the electric coupler with the tweezers and take out the power unit Step 4 Take a new power unit place and fix it and the electric coupler back with screws Note Please note the location...

Page 36: ...he power box housing Step 2 Unscrew four CM2x10mm screws and take down the hub board The receiving card is fixed at the back of the hub board Step 3 Unscrew one PWM2x4mm screw and take down the receiving card Step4 Take a new receiving card place it back and tighten it Step 5 Place back the hub board and tighten it Step 6 Place back the power box housing and lock four safety locks ...

Page 37: ... 11 7 Replacing the Tile Handle Step 1 Unscrew two PM5x26mm screws and take down the tile handle Step 2 Take a new tile handle place it back and tighten it 11 8 Replacing the Module Handle Step 1 Unscrew two screws and take down the module handle Step 2 Take a new module handle place it back and tighten it ...