The Follower zones are used with interior motion detectors and follow the
standard Exit Delay. If one enters the system through a Entry/Exit zone, then
the Follower zone will have the standard Entry Delay. If one enters the
system through a Follower zone without coming through an Entry/Exit zone,
an alarm will be generated.
This zone type cacn be forced arming programmed.
[3] 24-
HOUR
The 24-hour zones are permanently active. If such a zone is tripped, an alarm
will be generated even if the system is disarmed.
The second digit indicates the alarm type. There are 6 alarm types:
[0] C
ONTINUOUS
This kind of alarm sends an alarm message and enables the siren.
[1] P
ULSING
This kind of alarm sends an alarm message and enables the pulse siren.
[2] S
ILENT
This kind of alarm sends an alarm message only on phone lines and does
not enable the siren.
[3] C
ONTINUOUS
A
LARM
A
ND
F
ORCED
A
RMING
The zone sends an alarm message on phone lines and enables the siren.
The system can arm itself even if this zone is open when arming.
[4] P
ULSING
A
LARMING
AND
F
ORCED
A
RMING
The zone sends an alarm message on phone lines and enables the pulse
siren. The system can arm itself even if this zone is open when arming.
[5] S
ILENT
A
LARMING
AND
F
ORCED
A
RMING
The zone sends an alarm message on phone lines and does not enable the
pulse siren. The system can arm itself even if this zone is open when arming.
NOTE!
Forced arming alarming type is available only for
Entry/Exit
and
Follower
zones.
EXAMPLE: The zones should be programmed as follows:
- zone 1 - Entry/Exit with continuous alarm
- zone 2 - Follower with continuous alarm