3.8
Setting parameters in the MiR robot
A few parameters need to be updated in order to optimize the docking with the ROEQ system.
3.8.1
Setting the distance to marker (for disabling collision checks)
Step
Instruction
Illustration
1.
Connect to the robot via
web browser: mir.com
2.
In the MiR web
interface, go to:
System
→ Settings
→ Docking
and click
“Show advanced
settings”.
3.
Change the value in
“Distance to marker for
disabling collision
checks.” to 2.
Note: This will allow the
robot to dock to a
docking station when
equipment is attached.