EN
68
8
Function buttons and display
PROG
UP
DOWN
TEST
BUTTON
DESCRIPTION
UP
a
Next parameter
DOWN
b
Previous parameter
+
Increase value of parameter by 1
-
Decrease value of parameter by 1
PROG
Travel acquisition
TEST
Activate TEST mode
• Press the UP
c
and/or DOWN
b
buttons to view the parameter you intend to modify.
• Use the
+
and
-
buttons to modify the value of the parameter. The value starts to flash.
• Press and hold the
+
or
-
button to scroll quickly through values, to modify the parameter more quickly.
• To save the new value, wait a few seconds or move onto another parameter with the UP
a
or DOWN
b
button. The display
flashes rapidly to indicate that the new value has been saved.
• Parameters can only be modified while the motor is not running. Parameters can be viewed at any time.
9
Switching on or commissioning
Power the control unit.
The firmware version of the control unit is displayed briefly.
Version installed r3.50.
Immediately afterwards, the displays enters the commands and safety device status mode. See chapter 10.
Now set up the installation by configuring the parameters as needed.
For installations with two opposing barriers, settings must be made from the MASTER controller. Only the parameters
$
and
may be modified from the SLAVE controller.
10
Display function modes
10.1
Parameter display mode
PARAMETER
PARAMETER
VALUE
See chapter 12 for detailed descriptions of parameters.