11.2
Acquisition procedure:
AP P-
PH A5
AU to
PROG
x4 s
OPENING
OPEN
CLOSING
CLOSED
Yes
UNLOCK
LOCK
2x360°
2x360°
45°
PH A5
AU to
• Press and hold PROG for 4 seconds.
$3 3
is shown on the display.
• Unlock the barrier.
AGILIK-KB-BIONIK4HP-BIONIK6-BIONIK8
. Turn the key anticlockwise by two full turns.
BIONIK4
. Open the release cover.
• The barrier goes to 45° degree.
• After a few seconds, the message
3+ $6
is shown on the display. The controller unit launches a calibration procedure. The
operating parameters of the motor are determined during calibration.
• If the motor calibration procedure is successful, the message
3+ $
flashes on the display.
• To lock the barrier again
AGILIK-KB-BIONIK4HP-BIONIK6-BIONIK8.
Turn the key clockwise by two full turns.
BIONIK4
. Close the release cover and turn the key.
• The acquisition procedure now starts. The message
$XWR
is shown on the display and the barrier starts opening at low
speed.
• Once the barrier open mechanical stop is reached, the barrier stops briefly. The message
$XWR
flashes on the display.
• The barrier closes until it reaches the barrier closed mechanical stop.
If the acquisition procedure is completed successfully, the display enters the command and safety device state display mode.
If the following error messages are shown on the display, repeat the acquisition procedure:
•
QR 3+
: calibration procedure failed.
•
$3 3
.
(
: acquisition error.
For more information, see chapter 16 “Alarms and faults”.