Alarms and faults
PROBLEM
ALARM SIGNAL
POSSIBLE CAUSE
CORRECTIVE ACTION
The barrier does
not open or close.
POWER
LED off
No power.
Check power cable.
POWER
LED off
Fuses blown.
Replace fuse.
Always disconnect from mains power before removing
and refitting fuses.
)86(
Fuse F1 blown or damaged.
This message is not visible if con-
troller is in battery power mode.
Replace fuse.
Always disconnect from mains power before removing
and refitting fuses.
2) 6W
Input mains power voltage fault.
Controller initialisation failed.
Disconnect from mains power, wait 10 seconds then
reconnect to the mains and switch on.
We recommend replacing the control unit if the prob-
lem persists.
3U 2W
Overcurrent detected in inverter.
Press the
TEST
button twice or perform 3 command
requests in succession.
6(&2
Incorrect connection between
SEC1 and SEC2 of the transformer.
Swap the connection between SEC1 and SEC2.
G$ W$
Travel data acquisition error.
Check that the spring is balanced correctly with the
barrier unlocked.
Press TEST and check if any safety devices are in
alarm state.
Repeat acquisition procedure.
Calibration procedure failed
(
3+$6
).
Allow the indicated calibration times to elapse during
self-acquisition.
Before re-closing the release lock cover, ensure that
on the display will flash
3+$6
. Repeat acquisition
procedure.
Automation system position
selection modification message
with parameter
.
DX
SX
Motors for barriers are factory configured for right
hand opening barriers
(position of barrier rela-
tive to passage seen from inspection hatch side). If the
position is changed and message
'DWD
is displayed:
• Move the boom 45° degree.
• Adjust the spring position correctly for the required
opening direction.
• Press and hold
PROG
until
'$7$
disappears and
$33
appears on the display.
Repeat acquisition procedure.
Motor not connected.
Check the motor cable.
EU($
BreakAway system alarm.
• Check the setting of par.
.
• Check the correct
ACS/BA/60
system connection
to the control unit.
• Re-engage the boom.
• Consider replacing the boom if it is damaged.
Example:
HH
HH
Configuration parameter
error.
Set configuration value correctly and save.