00
No safety device in alarm state and no limit switch activated.
27
STOP contact (N.C.) open.
Jumper the STOP contact.
25
Sensing edge contact COS1 (N.C.) is open. Check connection. If sensing edge
is not installed, disable with
73 00
.
24
Sensing edge contact COS2 (N.C.) is open. Check connection. If sensing edge
is not installed, disable with
74 00
.
23
Photocell contact FT1 (N.C.) is open. Check connection. If photocell is not
installed, disable with
50 00
.
22
Photocell contact FT2 (N.C.) is open. Check connection. If photocell is not
installed, disable with
53 00
.
dATA
Incorrect travel length values / Parameter
71
modified: enabling absolute
encoder (only SMARTY Series).
• Disconnect from mains power or remove the main fuse (F3) and wait 5 seconds.
• Reconnect to mains power or refit the fuse.
• Press and hold PROG until the message
ATA
and
A
appear on the display.
Repeat acquisition procedure.
4. Before starting ...
d) Move the gate into the completely CLOSE position.
e) Press TEST button
Possible alarms and safety device messages:
SEE ACQUISITION PROCEDURE
PROG
TEST
+
-
PROG TEST
+
-
PROG
TEST
+
-
a) Select the automation system model installed with the parameter
A1
.
b) Select the number of motors installed with the parameter
70
.
This parameter is set for two motors by default.
c) Position the mechanical stops in both the open and closed positions by tightening them very tightly.
* the parameter
71 01
must be set and SMARTY/EMA installed for all applications with the SMARTY REVERSIBLE motor.
1 MOTOR
2 MOTORS
BE20/200/HS
SMARTY 5R5 *
BR20 Series
SMARTY 4HS
BH23/282
BH23/252/HS
BR21 Series
BR21/351/HS
SMARTY 5
BE20/400
SMARTY 7
MONOS4
SMARTY 7R *
BR20/400/R