ADL-2 User Manual.doc
2021-11-03
Page 10 of 12
Door open time [s]
Door opening time when access is granted. Default value: 3 s.
Limit attempts of entering PIN The maximal number of PIN entry attempts on lock’s keypad.
When exceeded then lock becomes temporary blocked. When set
to 0 then blocking is disabled. Default value: 0.
Lock\'s block time [min]
Lock blocking time when failed attempts limit is exceeded. Default
value: 3 min.
Buzzer volume level
Buzzer loudness level. Default value: 2.
Keypad backlight level
Keypad backlight level. Default value: 2.
Timeout between keys in PIN
[s]
Maximal time between two consecutive key pressings on lock
keypad. Default value: 6s.
Daylight saving time
Automatic switching between summer/winter time. Default value:
enabled.
PIN Block
PIN which blocks lock permanently. Default value: enabled.
PIN settings
PIN8
Parameters enables use of 8 digits PINs. Default value: enabled.
Shortened PINs
Parameter enables to define shortened PINs. Default value:
enabled.
List of blocked PINs
The list includes all blocked PINs (max. 255). When list is full then the newest PIN replaces the oldest
one.
Block
Command enables to block particular PIN.
Remove outdated
Command removes all blocked PINs which are outdated and
cannot be used anymore for access granting.
Remove all
Command removes all blocked PINs including ones which are not
outdated and could possibly be used for access granting.
Events
The list includes events registered in the lock. It is possible to send report in PDF format to specified
email address.
Identify device
Command activates acoustic and optical signalisation at ADL-2 lock. This is mainly used to identify
particular lock.
Remove lock
Command removes lock from the list of registered devices in Roger MDM app.
Memory reset
Memory reset erases all programmed PINs and restores factory configuration settings. In order to
perform memory reset procedure:
·
Remove jumper from the MEM pins (if applicable).
·
Short RST pins for a moment preferably by placing and removing jumper.
·
When acoustic signalization is started and orange LED indicator pulsates, place jumper on MEM
pins and the device will confirm memory reset with 3 acoustics beeps.