ADL-2 User Manual.doc
2021-11-03
Page 7 of 12
device, communication password and MAC BLE (data is available to read using Roger MDM
application). Additionally, it is possible to define a device description for easy identification.
Note: Once the device is added to particular account then it cannot be added to another account.
The 'PINs' button allows you to manage PIN codes for the selected lock. When generating a PIN of
the selected type, you can enter an email address and/or a phone number to which the notification
with the PIN code will be sent.
The 'Delete old PINs' button removes expired codes from the database (alternatively, you can hide
them from the view by selecting 'Hide expired').
PIN shortening
In case of PIN8 and PIN12 it is possible to shorten them to 6 digits and use them in the same way.
Use following command to shorten the PIN:
*3*[PIN]*[S]#
where [PIN] is PIN8 or PIN12 and [S] is shortened PIN.
Alternatively, shortened PINS can be generated with Roger MDM app in accordance with the section
Programming and configuration/PINs.
PIN blocking
Use following command to block particular PIN:
*1[PA]*[PIN]#
where [PA] is PIN Master and [PIN] is the one which is supposed to be blocked. Alternatively the PIN
can be blocked with Roger MDM app in accordance with the section
Programming and
configuration/List of blocked PINs.
Write the PIN on the card
In order to write the pin on the card, use the command *8*[PIN]#, where PIN is the code that is to
be saved on the card, and then put the proximity card against it.
Remove PIN from the card
To remove the PIN from the card, on the reader to which the PIN you want to remove is assigned, call
the command *8*00000000# (eight zeros), and then apply the proximity card.
LED indicators
ADL-2 lock is equipped with multicolour LED, which is dedicated to signal device states as in the table
below. In the bottom part of front panel there is located red LED to indicate battery level. When this
LED is on after PIN is entered then low battery level is reported and batteries must be replaced.
Signalling
Description
Red – ON
Red light during PIN entry signifies proper operation of the lock
Green – ON
Access granting, door unlocked.
Red – two pulses
Access denying – wrong PIN or the lock is blocked with PIN Block.
Blue – pulsing
Lock is communicating with smartphone.
Yellow – ON
Internal clock requires programming.
Yellow – pulsing
Lock fault. It is necessary to restore factory default setting and
reprogram the lock.