26
EN
26
15
ELECTRICAL CONNECTIONS
All electrical connections must be made with the unit
disconnected from mains power and, if applicable,
battery power.
See controller manual for instructions on making
connections and programming.
Before connecting to electrical power, ensure that the
mains power specifications on the identification plate
match the mains power supply used.
A switch or an omnipolar cut-off switch with a contact
opening of at least 3 mm must be installed on the mains
power line.
Ensure that an adequate residual current circuit breaker
and a suitable overcurrent cut-out are installed ahead of
the electrical installation.
Use a 3x2.5 mm
2
double insulated cable for the mains
power line.
Feed the cable on the left hand side of the barrier
through the rubber cable grommet on the left hand side
of the controller casing and connect it to the terminals
L (brown), N (blue) and
(yellow/green) inside the
automation unit.
Fasten the power cable with the cable grips included.
At least 50 mm of the connector cable conduit must
protrude from the holes in the base plate and into the
automation unit.
16
INSTALLING THE BATTERY KIT (OPTIONAL)
1. Disconnect the mains power.
2. Unscrew the screws and remove the head [
A
] (if applicable).
3. Lift the cable grommet [
B
] and disconnect the connector [
C
].
4. Open the transparent control unit cover [
D
].
5. Switch the control unit switch to the OFF position [
E
].
6. Lift the control unit and insert the batteries in their housing [
F
].
7. Connect the red, black and blue wires to the batteries (see detailed view)
8. Connect the batteries to the
+BATTERY
terminal (red wire) and
-BATTERY
terminal (black wire).
9. Insert the battery charge board BI/BCHP in the plug-in connector [
G
].
10. Reposition the control unit.
11. Switch the control unit switch to the ON position [
E
].
12. Reposition the transparent control unit cover [
D
].
13. Reconnect the connector [
C
] and close the cable grommet [
B
].
14. Close the head [
A
] and tighten the front screws.
15. Reconnect the mains power.
16
A
E
G
G
F
B
C
D
OFF
BLACK
RED
BATTERY (+)
BATTERY C
SEC2
BATTERY (-)
12
3
4
5
ROSSO/RED (+)
NERO/BLACK (-)
BLU/BLUE
L
N
Summary of Contents for BI/004
Page 1: ......