background image

PRT-EM Series Readers fv 1.29 and 2.29 Rev. J.doc   

 

 

 

2012-01-05 

 

Page 54 from 59 

Summary of Contents for PRT12EM

Page 1: ...25 kHz Access Terminals Firmware v1 29 and v2 29 Rev J This document refers to the following products PRT12EM PRT12EM BK PRT32EM PRT42EM PRT42EM BK PRT62EM PRT64EM PRT64EM VP PRT66EM Installation and...

Page 2: ...ys 8 4 OPERATING MODES 9 4 1 Terminal Mode 9 4 1 1 Wiegand Formats 9 4 1 2 Magstripe Formats 10 4 1 3 RACS Format 10 4 1 4 RS232 EPSO Protocol 9600 N 8 1 10 4 1 5 RS232 Cards and Keys 9600 N 8 1 10 4...

Page 3: ...G 24 6 1 Programming the PRT EM Readers without Keypad 24 6 1 1 Programming Through Multiple Readings of the Programming Card 24 6 1 2 Programming From The External Reader 25 6 2 Memory Reset 25 7 OPE...

Page 4: ...Unit ACU The logic device which provides access control usually it is an access controller XM 2 I O Extension Module The remote I O extension module for RACS system The XM 2 provides two NO NC inputs...

Page 5: ...from 59 RARC Program This program allows for programming and maintenance of the PRT series reader which are equipped with serial communication interface RogerISP Program This program allows for firmwa...

Page 6: ...re version for which manual is dedicated Using wrong version of manual may cause that device will not behave as described in document Also when you upgrade firmware in the reader assure that the new f...

Page 7: ...N s then providing subsequent transmission of such collected data to host ACU for further processing Reader offers several data transmission formats including popular Wiegand and Magstripe data protoc...

Page 8: ...version of RARC program it is possible to read and write card s Chip Serial Number 3 3 FUNCTION KEYS Some of the PRT EM series readers are equipped with two e g PRT12EM or one PRT42EM and PRT42EM BK...

Page 9: ...rotocol transactional protocol reader responses commands received from the host RS232 cards and individual keys RS232 cards and PIN s 4 1 1 Wiegand Formats When employing Wiegand transmission format d...

Page 10: ...host unit When in RACS mode triggering of the IN1 disables reading of the card and keypad This input can be used for temporary disabling of the reader The IN2 is not used in RACS mode 4 1 4 RS232 EPSO...

Page 11: ...igit long Each pressed key is buffered and transmitted as a whole PIN when key is pressed The key is treated as the end of the PIN Output format for cards STX DATA CR LF ETX 02 hex 10 hex digits coded...

Page 12: ...ted to 150 m For two way door control the primary reader needs to be configured for Full Standalone Mode while the secondary one slave needs to be set for RACS address ID 0 Note For Full Standalone Mo...

Page 13: ...and or PIN User Programming TOGGLE 0 119 TOGGLE users are authorized to unlock the controlled door and to switch reader between armed and disarmed mode they can have card and or PIN User Programming T...

Page 14: ...Card and PIN mode was set active on the unit Note With option Access disabled when reader armed the TOGGLE or TOGGLE LTD users may change reader s arming mode thus enabling or disabling access to a co...

Page 15: ...s input Attempt to arm the reader by means of TOGGLE or TOGGLE LTD users is rejected in following situations When input 23 Arming Disabled is active which might indicate that alarm system is not ready...

Page 16: ...ggered reader switches to Disarmed mode and remains in this state as long as line is active When reader s arming mode is controlled through input 24 the usage of TOGGLE and TOGGLE LTD card PIN is modi...

Page 17: ...rs will be immediately rejected by the reader reader will generate error sound and will not change its arming mode even for temporary time Note In some cases it can be essential to hide current arming...

Page 18: ...ting the reader from multiply tamper alarms The Tamper Alarm ceases automatically when Tamper Timer reaches the end or reader changes its arming mode 5 9 INTRUDER ALARM This alarm is dedicated to indi...

Page 19: ...ignaling time can be adjusted by General Alarm Timer This alarm ceases automatically when General Alarm Timer reaches the end or reader changes its arming mode 5 12 EVENTS RECORDING Reader is capable...

Page 20: ...ader has been programmed 302 Tamper Alarm Reader entered Tamper Alarm state 303 Intruder Alarm Reader entered Intruder Alarm state 305 Duress Alarm Reader entered Duress Alarm state 999 Unknown event...

Page 21: ...ut 7 Tamper Alarm 00 99 sec min 60 min Defines duration time for Tamper Alarm Programming timer to 00s makes that timer counts down for unlimited period till moment when reader changes it arming mode...

Page 22: ...the reader Acoustic Signals Signal Symbol Description One long signal Error unknown identifier access denied Three short beeps Command successfully completed OK signal Two short beeps Prompt signal th...

Page 23: ...g different card technologies can be used for installations with two card technologies The second PRT reader should be connected with main primary reader and configured for RACS address ID 0 The pair...

Page 24: ...d From the keypad located on the second slave reader 6 1 1 Programming Through Multiple Readings of the Programming Card Though some PRT EM readers are not equipped with keypad they can be programmed...

Page 25: ...it enables of programming new reader s operating mode and MASTER and INSTALLERS identifiers as well if required Memory Reset procedure 1 Power down the unit or place jumper on RST contacts 2 Remove a...

Page 26: ...be able to enter User Programming Also if you configure the reader for standalone operation mode but you don t program INSTALLER PIN card you will not be able to enter Installer Programming Note When...

Page 27: ...S232 9600 N 8 1 serial interface Each key entry is buffered once the key is pressed reader transmits entire PIN code as a single number max 16 digits long The key is treated as the end of PIN entry an...

Page 28: ...ler as a sequence of 6 bits EXXXXP where XXXX represents the code of the pressed key supplemented by two control bits E and P The E represents the even bit calculated from the first half of a transmit...

Page 29: ...ng PIN transmitted as Wiegand 32 bit stream without control bits 1 4 keys long PIN each key represented by 8 bit long codes key codes according to table A Reader sends data after four keys are pressed...

Page 30: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 30 from 59 4 4 0100 5 5 0101 6 6 0110 7 7 0111 8 8 1000 9 9 1001 A 1010 B 1011...

Page 31: ...s output 55 GH Programming function for IN1 GH 11 21 27 default GH 21 This command sets the function for IN1 input line located on the reader 56 GH Programming function for IN2 GH 11 21 27 default GH...

Page 32: ...conds or S 1 for minutes Setting S 1 and KL 00 is forbidden 69 S KL Programming Intruder Timer S 0 1 KL 00 99 default S 1 KL 60 This timer defines duration time for Intruder Alarm When S 0 and KL 00 a...

Page 33: ...ches to neutral mode again Note Use this function in case you want to keep secret current arming mode of the unit 78 L Programming Real Time Clock Control option L 0 1 default L 0 When L 0 reader cont...

Page 34: ...ignores electrical states on this line 21 Door Contact Input when shorted with supply minus indicates that controlled door is closed 22 Exit Button Input shorting this line with supply minus triggers...

Page 35: ...highest priority 47 Door Bell Output signals door bell for approx 5 seconds 48 AUX1 Toggle Output whenever F1 is pressed this output switches to opposite state regardless of the setting of AUX1 Timer...

Page 36: ...mmediately cleared When corresponding timer is set to 00s output it activated for unlimited time till moment when reader changes its arming mode again 58 Door Unlock Time Output line is triggered in t...

Page 37: ...essful card reading with an acoustic prompt signal two beep s for the next one to follow This function is ended automatically if no card is presented within 20 sec from the previous card presentation...

Page 38: ...IN if the user had card he still can use it 22 Card Delete a card The reader searches its memory for the presented card Once successful it removes it from the memory the location previously occupied b...

Page 39: ...2 29 Rev J doc 2012 01 05 Page 39 from 59 Press 0 Press 4 Press 5 Press command is completed The user with ID 45 has been deleted reader still remains in User Programming mode so that you may use your...

Page 40: ...PROGRAMMING VIA RS232 COM PORT In this scenario connection between programmed reader and PC requires four wires GND RXD TXD and RTS as presented on the drawing below however the programmed device mus...

Page 41: ...the PC is made through dedicated RUD 1 interface which is also used to supply programmed device no extra source of power is required Once the reader is connected to PC start RARC program select proper...

Page 42: ...of power Place jumper on FDM contacts Restart the reader short RST contacts for while Start RogerISP program and select COM port you have connected the reader Click on Erase command RARC program will...

Page 43: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 43 from 59...

Page 44: ...al type surface will reduce card reading distance For installations on a metal surface you can place a non metallic 10 mm thick spacer a plastic plaster plate etc between the reader and the supporting...

Page 45: ...n Wiegand and Magstripe this line controls LED OPEN Line is active when shorted to ground Blue IN2 Input line programmable function In Wiegand and Magstripe this line controls internal sunder of the r...

Page 46: ...contact 50mA 24V IP67 Proximity cards EM 125KHz EM4100 4102 compatible Communication distance Between access controller and PRT reader max 150 m Between main PRT reader and external PRT reader max 15...

Page 47: ...ray ABS enclosure pig tail cable PRT64EM Outdoor proximity reader with keypad laser engraved long durability silicon rubber keypad two function keys dark grey ABS enclosure screw terminals pig tail ca...

Page 48: ...tes Programming functions 51 and 52 removed and replaced by functions 71 and 72 v1 0 fv1 25 19 05 08 CLK line operation in Simple Standalone Mode corrected Door Bell indication on internal buzzer and...

Page 49: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 49 from 59 User list Reader name Reader location ID Card code PIN Type User Name None MASTER None INSTALLER...

Page 50: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 50 from 59...

Page 51: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 51 from 59...

Page 52: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 52 from 59...

Page 53: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 53 from 59...

Page 54: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 54 from 59...

Page 55: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 55 from 59...

Page 56: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 56 from 59...

Page 57: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 57 from 59...

Page 58: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 58 from 59...

Page 59: ...gh waste bin on wheels means that the product must be disposed of at a separate collection point This also applies to the product and all accessories marked with this symbol Products labeled as such m...

Reviews: