Proximity cards 

Mifare Ultralight/Classic/Plus/DESFire 

Supply voltage 

Nominal 12VDC, min./max. range 10-15VDC 

Avg. current consumption 

130 mA for 12VDC 

Inputs 

Two  (IN1,IN2)  NO  inputs,  electrically  biased  to  +12V  via  15kΩ 
resistor, triggering level approx. 3.5V 

Ethernet 

10BASE-T 10/100Mb Ethernet communication port 

Port RS485 

RS485 communication port 

Tamper 

Isolated contact, NC type, 24V/50 mA rated 

Environmental 

class 

(according to EN 50131-1) 

Class  I,  indoor  general  conditions,  temperature:  +5°C  to  +40°C, 
relative humidity: 10 to 95% (no condensation) 

IP code 

IP41 

Dimensions H x W x D 

85mm x 85mm x 52mm 

Weight 

160g 

Certificates 

CE 

3.

 

I

NSTALLATION

 

3.1 Terminals and connection diagram 

 

 

Fig. 2 RFT1000 terminals 

Table 2. RFT1000 terminals 

Terminal 

Description 

12V  

Positive power supply contact, 12VDC 

GND 

Negative  power  supply  contact  and  reference  potential  for  RS485 

communication bus and input lines 

TMP 

Tamper switch, 24V/50mA 

TMP 

Tamper switch, 24V/50mA 

IN1 

IN1 input line 

IN2 

IN2 input line 

Summary of Contents for RFT1000

Page 1: ...on 1 3 or newer Hardware version 1 1 Document version Rev A 2016 ROGER sp z o o sp k All rights reserved This document is subject to the Terms of Use in their current version published at the www roger pl website of the Roger sp z o o sp k company hereinafter referred to as ROGER ...

Page 2: ...3 6 Use installation guidelines 6 4 Configuration 7 4 1 Low level configuration RogerVDM 7 4 1 1 Configuration of communication parameters 7 4 1 2 Recognition modes 8 4 1 4 Inputs 9 4 2 Communication with RFT1000 VISO 10 4 3 User enrolment in 1 N mode 10 4 4 User enrolment in 1 1 mode 10 4 4 1 Master Authorisation 11 4 5 User identification 11 4 6 Full memory reset 12 4 7 Firmware update 12 5 Orde...

Page 3: ...e Attendance terminal in RACS 5 system RFT1000 is equipped with fingerprint scanner and Mifare Ultraligth Classic Plus DESFire proximity card reader Users can be identified by comparison of their fingerprints with fingerprint templates recorded in reader s memory 1 N mode or by comparison of their fingerprints with fingerprint templates recorded in Mifare card memory 1 1 mode The reader is not a s...

Page 4: ...ntact NC type 24V 50 mA rated Environmental class according to EN 50131 1 Class I indoor general conditions temperature 5 C to 40 C relative humidity 10 to 95 no condensation IP code IP41 Dimensions H x W x D 85mm x 85mm x 52mm Weight 160g Certificates CE 3 INSTALLATION 3 1 Terminals and connection diagram Fig 2 RFT1000 terminals Table 2 RFT1000 terminals Terminal Description 12V Positive power su...

Page 5: ... indicators on its enclosure which function according to table 3 Table 3 LED indicators Symbol Name Colour Description STATUS Red Green Armed Disarmed mode of reader OPEN Green Door unlocked SYSTEM Orange Various signalling functions e g microcontroller memory failure configuration errors etc 3 3 Power supply RFT1000 reader requires 12 VDC supply voltage The supply must be connected to 12V termina...

Page 6: ...protector from fingerprint scanner Otherwise it may hinder fingerprint scanning In case of connection through Ethernet port twisted pair cable should be uninsulated in the shortest possible distance and wires should remain twisted in the longest possible distance It is required to install proximity card readers in minimal distance of 0 5m from each other In order to ensure correct operation of the...

Page 7: ...with default empty password Connection and configuration procedure 1 Connect the reader to computer by means of Ethernet port 2 Configure your computer s network parameters according to RFT1000 default settings The IP address of the computer must be in the same subnet i e 192 168 0 xxx 3 Install and start RogerVDM software 4 In the opened window fig 6 select RFT1000 v1 0 device firmware 1 3 and Et...

Page 8: ...eld assign unoccupied address to RFT1000 on RS485 bus of MC16 access controller in range of 100 115 10 Upload settings to the reader with Send to Device button 4 1 2 Recognition modes In case of RFT1000 it is necessary to select one of following recognition modes 1 N mode templates in reader s memory in this mode fingerprint templates are recorded in memory database of RFT1000 reader Users are ide...

Page 9: ...nu of RogerVDM software fig 7 When RFT1000 reader is installed in RACS 5 system only the function 5 Card Reader Mode is applicable Other available functions are used beyond RACS systems In general input functions of Roger devices depending on assigned functions can be momentary or constant type Therefore device may detect only activation of input momentary type or activation and deactivation of in...

Page 10: ... Readers icon 2 In the opened window select Add button and enter communication parameters which were previously configured with RogerVDM including IP address port and communication password 3 Verify settings with Test connection button 4 3 User enrolment in 1 N mode In 1 N mode user enrolment including fingerprint scanning and assignment of access rights is done in VISO software It is recommended ...

Page 11: ... store 1 fingerprint template while Mifare Classic 4k card can store up to 7 fingerprint templates Mifare Ultralight cards do not have enough memory to store any fingerprint template 4 5 User identification User identification by RFT1000 reader depends on selected recognition mode section 4 2 1 input with function 5 Card Reader Mode section 4 1 4 and the option Card reader mode fig 7 Input 5 is us...

Page 12: ...ncluding users data base and restores factory default settings Reset procedure 1 Switch off power supply to RFT1000 2 Remove connections to CLK and IN2 terminals 3 Connect CLK terminal with IN2 terminal 4 Switch on power supply to RFT1000 The reader shall generate continuous acoustic signal 5 Disconnect CLK and IN2 terminals Communication parameters after reset IP address 192 168 0 70 Subnet mask ...

Page 13: ...uct or packaging indicates that the product should not be disposed of with other wastes as this may have a negative impact on the environment and health The user is obliged to deliver equipment to the designated collection points of electric and electronic waste For detailed information on recycling contact your local authorities waste disposal company or point of purchase Separate collection and ...