RFT1000 in RACS 5 User Manual.doc
2017-10-05
5/13
CLK
RACS CLK/DTA bus – not applicable in RACS 5
DTA
RACS CLK/DTA bus – not applicable in RACS 5
A
RS485 communication bus (line A)
B
RS485 communication bus (line B)
1,2,3,4,5,6,7,8
Ethernet port terminal
Fig. 3 Connection diagram for RFT1000 reader and MC16-PAC-1 access controller
3.2 LED indicators
RFT1000 reader is equipped with three LED indicators on its enclosure which function according to
table 3.
Table 3. LED indicators
Symbol
Name
Colour
Description
STATUS
Red/Green
Armed/Disarmed mode of reader
OPEN
Green
Door unlocked
SYSTEM
Orange
Various signalling functions, e.g. microcontroller
memory failure, configuration errors, etc.
3.3 Power supply
RFT1000 reader requires 12 VDC supply voltage. The supply must be connected to +12V terminal
and GND terminal. The GND terminal is also reference potential for RS485 bus and IN1, IN2 input
lines. All devices, which are connected to the same RS485 bus should have common ground (GND).