from the lock’s memory. Once option is set it can be cleared by 

memory reset procedure only. The purpose of the option is to 
prevent unauthorized person to read card numbers from the lock’s 

memory. Default value: No. 

Don't disturb knob switch 

When option is set (Yes), rotating the knob switch located on the 
internal escutcheon will disable access to the room by means of 

cards. Each time door is opened using handle, knob switch returns 
to off position. Default value: No (option off). 

Wireless settings 

Device MAC address 

Factory set RWL-1 lock identification number. 

Hub MAC address 

The identification number of the wireless hub (e.g. RWH-1) to 
which lock may connect.  

Radio channels 

Radio channels enabled to be used by lock. It is recommended to 
allow all channels on the lock and restrict radio channels on the 
hub. Default value: all channels available. 

Network identifier 

The identification number of the wireless network in which lock 
operates (PAN ID). Each network working on the same radio 
channel should be assigned with unique PAN ID. The range of 

available values is 0-16. Optionally the parameter can be set to 
AUTO. In such case the hub shall select PAN ID automatically. 

Default value: AUTO. 

Encryption key 

Encryption key used for wireless communication. In case of 
recommended empty field the key shall be defined and applied 

automatically when the network is defined. Default value: Auto. 

Notification time [s] 

The parameter defines how often the lock shall wake from standby 
mode and shall communicate with hub to confirm its availability in 

the network. The shorter is the notification time the more often 
communication is established and batteries are discharged quicker. 

Default value: 60s. 

Registration time [s] 

The parameter defines the time necessary to read card at the lock 
in order to add the lock to the network. If the time is exceeded 

then lock adding procedure must be started from the beginning. 
This parameter concerns network establishing procedure only. 

Default value: 600s. 

Network  restore attempt time 
[min.] 

The parameter defines time between consecutive attempts to 
restore wireless communication with the hub when it is broken due 

to some reason. Default value: 30min. 

Radio channel 

The parameter indicates radio channel used by the lock. This 
parameter is read-only and appears only if the lock is successfully 

enrolled into the network. 

Network ID 

The parameter indicates network ID (PAN ID) in which lock 
operates. This parameter is read-only and appears only if the lock 

is successfully enrolled into the network.  

Dynamic user list 

The parameter enables dynamic user list. Users from the list can 
be granted access when the communication with lock is lost. 

Default value: Yes. 

Dynamic user timeout [s] 

The parameter specifies how long each card on dynamic user list is 

stored and consequently can be granted access. The time is 
counted from the latest use of the card. Default value: 3600. 

Summary of Contents for RWL-1 series

Page 1: ...Roger Access Control System RWL 1 Wireless Lock Operating Manual Firmware version 1 1 Document version Rev F ...

Page 2: ... is separated from the deadbolt and moves freely When the access is granted the electronic module couples the external handle with deadbolt and latch to enable door opening When the door is closed then the deadbolt is relocked automatically in order to protect door against unauthorized opening The RWL 1 lock can be optionally equipped with door cylinder and then be opened from the outside with tra...

Page 3: ...der G which can be used for emergency door opening with mechanical key The electronic module which is located inside the escutcheon includes service pins B and programming pins C Wires with larger plug D are used to connect the electronic module with mortise lock and wires with smaller plug E are used to connect the module with battery pack Two isolated wires F ended with heat shrinkable sleeve ar...

Page 4: ...the mortise lock In Online mode the status of knob is reported to access controller with KNOB SWITCH input which can be further configured in VISO management software In Offline mode the door can be locked with the knob switch and then it cannot be opened from the outside using proximity card When the handle is twisted then the knob reverts to normal position The internal escutcheon includes also ...

Page 5: ...rvomechanism controlled by electronic module External handle is coupled momentary whenever access is granted When the RWL 1 is operated in Office mode then external handle is coupled permanently Handle spacing i e distance from handle to cylinder in the mortise lock equals to 72mm Fig 6 Mortise lock Door cylinder RWL 1 lock is adapted to door cylinder installation Such cylinder enables emergency d...

Page 6: ... encrypted with own key in order to enable protection against card copying Due to relatively easy copying of the card serial numbers CSN it is recommended to configure the lock for operation with programmable card numbers PCN Offline mode In the Offline mode the lock grants access for cards stored in its memory The lock can operate permanently in Offline mode or enter this mode temporary when wire...

Page 7: ...ess connection is lost If the Emergency mode is not configured in RACS 5 AIR system then there is a risk that mentioned disturbances will affect the system and hinder its operation Radio channels The wireless communication utilizes the IEEE 802 15 4 2 4GHz band which is shared with Wi Fi networks If the lock uses the same channel as Wi Fi network then in case of intensive Wi Fi transmission the lo...

Page 8: ...mode user list and can grant the access according to the description given in section Offline mode The card can be granted access if it is stored on any of two mentioned user lists LED indicators RWL 1 lock is equipped with 4 LED indicators which functions are described in the table below LED indicators Name Colour Description LED RED Red Online mode the function of this LED is programmed in VISO ...

Page 9: ...DD ADD programming card New card adding to the lock DEL DEL programming card Card deleting from the lock Configuration recovery from the lock In some circumstances it might be required to recover the configuration settings from the lock Such operation can be done by means of RogerVDM software Regardless of the operating mode it is not possible to recover communication password and card encryption ...

Page 10: ...d to program user s Main card Read second card to program user s Backup card Wait till 3 acoustic beeps are generated by lock and then you can continue with more cards programming Example Programming of user with Normal access and Office access Read ADD programming card thrice Read first card to program user s Main card Read second card to program user s Backup card Wait till 3 acoustic beeps are ...

Page 11: ...e LED SYSTEM shall pulsate 4 In RogerVDM select Device New and then select type of device RWL 1 and serial COM port with RUD 1 interface 5 Select required settings 6 Make backup by saving settings to file button Send to File 7 Upload settings to the lock button Send to device 8 In RogerVDM select Device Disconnect 9 Remove jumper from MEM pins 10 Short RST pins for a moment preferably by placing a...

Page 12: ...on LED SYSTEM Default value Yes Short sound after card read When option is set then card reading is confirmed with short acoustic beep Default value Yes LED SYSTEM pulsing when card close to the reader When option is set then orange LED SYSTEM pulses whenever card is detected near the reader Default value No Battery low level signalisation When option is set then lock signals low battery level by ...

Page 13: ...d automatically when the network is defined Default value Auto Notification time s The parameter defines how often the lock shall wake from standby mode and shall communicate with hub to confirm its availability in the network The shorter is the notification time the more often communication is established and batteries are discharged quicker Default value 60s Registration time s The parameter def...

Page 14: ...sents output which controls LED RED Default value LED red LED GREEN comment Any text to be displayed in VISO management software in order to facilitate object identification LED GREEN object represents output which controls LED GREEN Default value LED green LED SYSTEM comment Any text to be displayed in VISO management software in order to facilitate object identification LED SYSTEM object represe...

Page 15: ...the card s memory Default value BIN First byte position FBP The parameter specifies the position of the most significant byte MSB of programmable card number PCN Default value 0 Last byte position LBP The parameter specifies the position of the least significant byte LSB of programmable card number PCN Default value 7 Sector ID The parameter specifies sector number in card s memory where programma...

Page 16: ...ment preferably by placing and removing jumper When acoustic signalization is started place jumper on MEM pins and the devices shall confirm memory reset with 2 acoustics beeps Read any proximity card and it shall be new ADD programming card Read any proximity card and it shall be new DEL programming card Wait for 3 acoustic beeps The lock shall restore default factory settings and shall switch to...

Page 17: ...o EN 50131 1 Class I indoor general conditions temperature 5 C to 40 C relative humidity 10 to 95 no condensation IP code IP40 Dimensions 78 x 242mm Weight Approx 2200g Certificates CE Ordering information Product Description RWH 1 RACS 5 AIR wireless hub RWL 1 LI Wireless door lock with escutcheons left hand RWL 1 RI Wireless door lock with escutcheons right hand RWL 1 LO Wireless door lock with ...

Page 18: ...lectric and electronic waste For detailed information on recycling contact your local authorities waste disposal company or point of purchase Separate collection and recycling of this type of waste contributes to the protection of the natural resources and is safe to health and the environment Weight of the equipment is specified in the document Contact Roger sp z o o sp k 82 400 Sztum Gościszewo ...