RWL-1 Operating Manual.doc
2020-03-25
15/18
Input response time
DEADBOLT
Parameter defines minimal duration of pulse [ms] which is required
to trigger the input DEADBOLT. Default value: 50ms.
KNOB SWITCH
Parameter defines minimal duration of pulse [ms] which is required
to trigger the input KNOB SWITCH. Default value: 50ms.
DOOR CONTACT
Parameter defines minimal duration of pulse [ms] which is required
to trigger the input DOOR CONTACT. Default value: 50ms.
Reader settings
Reader object type
The parameter defines type of data returned to controller by lock’s
card reader. Based on this parameter the controller recognizes
card number. Default value: 40 bit number.
Advanced card read settings
CSN length
The parameter defines number of bytes taken from the card serial
number (CSN) and applied in the returned card number (RCN).
Default value: 8.
Mifare Classic settings
Sector type
When the parameter is enabled then returned card number (RCN)
is composed of two parts: the programmable card number (PCN)
and the card serial number (CSN).
When the option is disabled then the returned card number (RCN)
is composed of the card serial number (CSN) only.
Default value: None.
Format
The format of the programmable card number (PCN) stored in the
card’s memory. Default value: BIN.
First byte position (FBP)
The parameter specifies the position of the most significant byte
(MSB) of programmable card number (PCN). Default value: 0.
Last byte position (LBP)
The parameter specifies the position of the least significant byte
(LSB) of programmable card number (PCN). Default value: 7.
Sector ID
The parameter specifies sector number in card’s memory where
programmable card number (PCN) is stored. Default value: 0.
Application ID
The parameter Application ID (AID) is located in card’s MAD sector
and it specifies the sector where programmable card number
(PCN) is stored if the
Sector type
(see above) is configured as
MAD. Default value: 5156 (Roger AID).
Block ID
The parameter specifies the block number where programmable
card number (PCN) is stored in a particular sector of card’s
memory. For sectors 0-31, blocks 0-2 are available while for
sectors 32-39, blocks 0-14 are available. Default value: 0.
Key type
The parameter specifies key type used for encryption of data in
card’s memory. Default value: A.
Key
The parameter specifies 6-byte key used to encrypt data in card’s
memory. Default value: FF...FF.
Users
Credentials
tab in RogerVDM top menu enables management of the cards programmed in the lock’s
memory. As explained earlier, lock can operate with 50 users with
Main card
and
Backup card
or 100
users with
Main card
only. Each user can be granted with
Normal access
and/or
Office mode