RWL-1 Operating Manual.doc
2020-03-25
3/18
Fig. 2. RWL-1 lock in outward opening doors while standing outside
Mechanical construction
External part of RWL-1
The external part of RWL-1 consists of escutcheon with handle and it is dedicated to installation at the
entry to controlled room. The escutcheon includes card reader (A) and hole for door cylinder (G)
which can be used for emergency door opening with mechanical key. The electronic module which is
located inside the escutcheon includes service pins (B) and programming pins (C). Wires with larger
plug (D) are used to connect the electronic module with mortise lock and wires with smaller plug (E)
are used to connect the module with battery pack. Two isolated wires (F) ended with heat shrinkable
sleeve are used to connect external door contact. The status of the contact is represented by DOOR
CONTACT input in RACS 5 system.
Fig. 3. External part of RWL-1