RWL-1-SL Operating Manual.doc
2021-12-20
10/13
Load defaults
Restore default settings
Read from File…
Load backup configuration
Send to File...
Save backup configuration
Read from Device
Reads configuration from device
Send to Device
Upload configuration to device
Tab: Credentials
Add
Adds new user
Edit
Edit existing user
Delete
Delete existing user
Delete all
Delete all users
Read from file
Read users list from file
Write to file
Save users list to file
Read from device
Read users list from device
Send to device
Save users list to device
RWL-1-SL configuration parameters in RogerVDM
The table below includes RWL-1-SL configuration parameters which can be modified using RogerVDM
software within low level configuration of device (tab:
Configuration
).
Parameter
Function
General settings
LED SYSTEM flash after card
read
When option is set then card reading is confirmed with flash on
LED SYSTEM. Default value: Yes.
Short sound after card read
When option is set then card reading is confirmed with short
acoustic beep. Default value: Yes.
LED SYSTEM pulsing when
card close to the reader
When option is set then orange LED SYSTEM pulses whenever card
is detected near the reader. Default value: No.
Battery low level signalisation When option is set then lock signals low battery level by orange
LED SYSTEM indicator pulsing and series of 5 acoustic beeps after
card reading. Default value: Yes.
Buzzer loudness level
The parameter defines loudness level of the built-in buzzer. When
set to zero then buzzer is disabled. Default value: 100%
Standalone mode
Lock pulse [s]
The parameter defines lock opening time when access is granted.
Default value: 2s.
ADD programming card
The card code of the ADD programming card.
DEL programming card
The card code of the DEL programming card.
Backup cards
When option is on, then each user programmed in the lock can
have both
Main card
and
Backup card
. When the option is off then
each user can have the
Main card
only. Default value: Yes.
Card codes protection
When option is set then it is not possible to read user card codes
from the lock’s memory. Once option is set it can be cleared by
memory reset procedure only. The purpose of the option is to