RWL-1-SL Operating Manual.doc 

 

2021-12-20 

 

10/13 

 

Load defaults 

Restore default settings 

Read from File… 

Load backup configuration 

Send to File... 

Save backup configuration 

Read from Device 

Reads configuration from device 

Send to Device 

Upload configuration to device 

Tab: Credentials 

Add 

Adds new user 

Edit 

Edit existing user 

Delete 

Delete existing user 

Delete all 

Delete all users 

Read from file 

Read users list from file 

Write to file 

Save users list to file 

Read from device 

Read users list from device 

Send to device 

Save users list to device 

RWL-1-SL configuration parameters in RogerVDM 

The table below includes RWL-1-SL configuration parameters which can be modified using RogerVDM 
software within low level configuration of device (tab: 

Configuration

). 

Parameter 

Function 

General settings 

LED SYSTEM flash after card 
read  

When option is set then card reading is confirmed with flash on 
LED SYSTEM. Default value: Yes. 

Short sound after card read 

When option is set then card reading is confirmed with short 
acoustic beep. Default value: Yes. 

LED SYSTEM pulsing when 

card close to the reader 

When option is set then orange LED SYSTEM pulses whenever card 

is detected near the reader. Default value: No. 

Battery low level signalisation  When option is set then lock signals low battery level by orange 

LED SYSTEM indicator pulsing and series of 5 acoustic beeps after 

card reading. Default value: Yes. 

Buzzer loudness level 

The parameter defines loudness level of the built-in buzzer. When 
set to zero then buzzer is disabled. Default value: 100% 

Standalone mode 

Lock pulse [s] 

The parameter defines lock opening time when access is granted. 
Default value: 2s. 

ADD programming card 

The card code of the ADD programming card. 

DEL programming card 

The card code of the DEL programming card. 

Backup cards 

When option is on, then each user programmed in the lock can 
have both 

Main card

 and 

Backup card

. When the option is off then 

each user can have the 

Main card

 only. Default value: Yes. 

Card codes protection 

When option is set then it is not possible to read user card codes 
from the lock’s memory. Once option is set it can be cleared by 

memory reset procedure only. The purpose of the option is to 

Summary of Contents for RWL-1-SL

Page 1: ...Roger Access Control System RWL 1 SL Standalone Door Lock Operating Manual Firmware version 1 1 Document version Rev A ...

Page 2: ... electronic module couples the external handle with deadbolt and latch to enable door opening When the door is closed then the deadbolt is relocked automatically in order to protect door against unauthorized opening The RWL 1 SL lock can be optionally equipped with door cylinder and then be opened from the outside with traditional metal key The RWL 1 SL is equipped with knob switch position detect...

Page 3: ...led room The escutcheon includes card reader A and hole for door cylinder G which can be used for emergency door opening with mechanical key The electronic module which is located inside the escutcheon includes service pins B and programming pins C Wires with larger plug D are used to connect the electronic module with mortise lock and wires with smaller plug E are used to connect the module with ...

Page 4: ...its status using cable with connector I The connector can be plugged into socket K at the mortise lock The door can be locked with the knob switch and then it cannot be opened from the outside using proximity card When the handle is twisted then the knob reverts to normal position The internal escutcheon includes also battery pack J In order to replace batteries unscrew two top bolts and pull the ...

Page 5: ...tronic module External handle is coupled momentary whenever access is granted When the RWL 1 SL is operated in Office mode then external handle is coupled permanently Handle spacing i e distance from handle to cylinder in the mortise lock equals to 72mm Fig 6 Mortise lock Door cylinder RWL 1 SL lock is adapted to door cylinder installation Such cylinder enables emergency door opening from the outs...

Page 6: ...alone Access Control The lock grants access for cards stored in its memory Up to 100 cards can be defined and stored in lock s memory Each card can be authorised for momentary door opening option Normal access and or to open the door for unlimited time option Office access If the card is authorized for Normal access then it opens the lock for the time specified by the parameter Lock pulse If the c...

Page 7: ...red with 2 programming cards ADD card and DEL card Lock pulse by default is set to 2 sec while built in RFID reader is configured to read card serial numbers CSN Factory cards Label Name Authorization ADD ADD programming card New card adding to the lock DEL DEL programming card Card deleting from the lock Configuration recovery from the lock In some circumstances it might be required to recover th...

Page 8: ...d to program user s Main card Read second card to program user s Backup card Wait till 3 acoustic beeps are generated by lock and then you can continue with more cards programming Example Programming of user with Office access Read ADD programming card twice Read first card to program user s Main card Read second card to program user s Backup card Wait till 3 acoustic beeps are generated by lock a...

Page 9: ... to configure the lock using computer and RogerVDM software 1 Place jumper on MEM pins 2 Connect the lock to RUD 1 interface using dedicated cable fig 6 3 Short RST pins for a moment preferably by placing and removing jumper Orange LED SYSTEM shall pulsate 4 In RogerVDM select Device New and then select type of device RWL 1 SL and serial COM port with RUD 1 interface 5 Select required settings 6 M...

Page 10: ...onfirmed with short acoustic beep Default value Yes LED SYSTEM pulsing when card close to the reader When option is set then orange LED SYSTEM pulses whenever card is detected near the reader Default value No Battery low level signalisation When option is set then lock signals low battery level by orange LED SYSTEM indicator pulsing and series of 5 acoustic beeps after card reading Default value Y...

Page 11: ... value 0 Application ID The parameter Application ID AID is located in card s MAD sector and it specifies the sector where programmable card number PCN is stored if the Sector type see above is configured as MAD Default value 5156 Roger AID Block ID The parameter specifies the block number where programmable card number PCN is stored in a particular sector of card s memory For sectors 0 31 blocks ...

Page 12: ...installation make sure that door cylinder is long enough Lock installation Make holes in door using drilling template In case of non rebated door it might be necessary to use metal plate Both drilling template and metal plate are included in the factory new set Install mortise lock in such a way that marks which specify proper location of handle pin will be aligned fig 6 Lead K and L groups of wir...

Page 13: ... of the product This symbol placed on a product or packaging indicates that the product should not be disposed of with other wastes as this may have a negative impact on the environment and health The user is obliged to deliver equipment to the designated collection points of electric and electronic waste For detailed information on recycling contact your local authorities waste disposal company o...

Reviews: