background image

RWL-1-SL Operating Manual.doc 

 

2021-12-20 

 

6/13 

 

programming computer with the RogerVDM application and connected to the lock through RUD-1 
communication interface. If the lock is designated to operate with list of 50 users, each equipped with 

Main card

 and 

Backup card

, it can be programmed manually without computer. In this scenario, two 

programming cards, called ADD card and DEL card, are used to program the unit.  

Note: Due to the small size of the proximity keyfobs, they may be incorrectly detected by the built-in 
proximity sensor. In the RWL series locks, it is recommended to use full-size ISO proximity cards. 

Proximity cards 

The lock is equipped with a card reader which supports MIFARE® cards. Factory configured device 

reads card serial number (CSN - 

Chip Serial Number

), but using RogerVDM software it can be 

configured to use programmable card number (PCN – 

Programmable Card Number

) stored in the 

encrypted memory of the MIFARE card.  

Card number 

The card number which RWL-1-SL lock reads from the card and returns to the access controller is 
called RCN (

Returned Card Number

). In general, the RCN can be composed of two sections: 

·

 

CSN section 

·

 

PCN section 

The CSN section is a part of the RCN card number taken from the card serial number (CSN). The 
serial number is programmed by card manufacturer. 

The PCN section is a part of the RCN card number taken from the card’s programmable memory. The 

programmable number can be encrypted with own key in order to enable protection against card 
copying. 
 Due to relatively easy copying of the card serial numbers (CSN), it is recommended to configure the 
lock for operation with programmable card numbers (PCN). 

Standalone Access Control 

The lock grants access for cards stored in its memory. Up to 100 cards can be defined and stored in 

lock’s memory. Each card can be authorised for momentary door opening (option: 

Normal access

and/or to open the door for unlimited time (option: 

Office access

). If the card is authorized for 

Normal 

access

 then it opens the lock for the time specified by the parameter 

Lock pulse

. If the card is 

authorized for 

Office mode 

 then it can open the lock for unlimited time. When lock is switched to 

Office mode 

door can be open without use of a card. If the card is authorised for 

Normal access

 and 

Office mode

 then in order to get normal access it must be used once while in order to activate 

Office 

mode 

it must be used twice. 

The access to a room from the outside can be blocked with knob switch located at the internal 
escutcheon. The functioning of knob can be disabled with the parameter 

Don't disturb knob switch.

 

Backup cards 

Up to 100 cards can be defined and stored in lock’s memory. Each card can belong to individual user. 

Optionally the lock can operate with 50 users only. In such a case each user can have two cards: 

Main 

card

 and 

Backup card

. Both cards have the same authorizations and the enrolment of 

Backup card

 is 

optional. Factory new lock is configured to operate with 50 users. This mode is also used when lock’s 
default settings are restored. Switching to 100 users mode can be done only by means of RogerVDM 
software. The main benefit of 

Backup cards

 is to enable selective removing of 

Main cards

 from the 

lock’s memory even if such 

Main cards

  are not physically available (e.g. lost or damaged). Therefore 

it is recommended to mark and store 

Backup cards

 in designated place for future use. 

Note: 

Backup card

 is assigned with same authorizations as accompanying 

Main card

 and can be used 

in the same way as the 

Main card

.  

Summary of Contents for RWL-1-SL

Page 1: ...Roger Access Control System RWL 1 SL Standalone Door Lock Operating Manual Firmware version 1 1 Document version Rev A ...

Page 2: ... electronic module couples the external handle with deadbolt and latch to enable door opening When the door is closed then the deadbolt is relocked automatically in order to protect door against unauthorized opening The RWL 1 SL lock can be optionally equipped with door cylinder and then be opened from the outside with traditional metal key The RWL 1 SL is equipped with knob switch position detect...

Page 3: ...led room The escutcheon includes card reader A and hole for door cylinder G which can be used for emergency door opening with mechanical key The electronic module which is located inside the escutcheon includes service pins B and programming pins C Wires with larger plug D are used to connect the electronic module with mortise lock and wires with smaller plug E are used to connect the module with ...

Page 4: ...its status using cable with connector I The connector can be plugged into socket K at the mortise lock The door can be locked with the knob switch and then it cannot be opened from the outside using proximity card When the handle is twisted then the knob reverts to normal position The internal escutcheon includes also battery pack J In order to replace batteries unscrew two top bolts and pull the ...

Page 5: ...tronic module External handle is coupled momentary whenever access is granted When the RWL 1 SL is operated in Office mode then external handle is coupled permanently Handle spacing i e distance from handle to cylinder in the mortise lock equals to 72mm Fig 6 Mortise lock Door cylinder RWL 1 SL lock is adapted to door cylinder installation Such cylinder enables emergency door opening from the outs...

Page 6: ...alone Access Control The lock grants access for cards stored in its memory Up to 100 cards can be defined and stored in lock s memory Each card can be authorised for momentary door opening option Normal access and or to open the door for unlimited time option Office access If the card is authorized for Normal access then it opens the lock for the time specified by the parameter Lock pulse If the c...

Page 7: ...red with 2 programming cards ADD card and DEL card Lock pulse by default is set to 2 sec while built in RFID reader is configured to read card serial numbers CSN Factory cards Label Name Authorization ADD ADD programming card New card adding to the lock DEL DEL programming card Card deleting from the lock Configuration recovery from the lock In some circumstances it might be required to recover th...

Page 8: ...d to program user s Main card Read second card to program user s Backup card Wait till 3 acoustic beeps are generated by lock and then you can continue with more cards programming Example Programming of user with Office access Read ADD programming card twice Read first card to program user s Main card Read second card to program user s Backup card Wait till 3 acoustic beeps are generated by lock a...

Page 9: ... to configure the lock using computer and RogerVDM software 1 Place jumper on MEM pins 2 Connect the lock to RUD 1 interface using dedicated cable fig 6 3 Short RST pins for a moment preferably by placing and removing jumper Orange LED SYSTEM shall pulsate 4 In RogerVDM select Device New and then select type of device RWL 1 SL and serial COM port with RUD 1 interface 5 Select required settings 6 M...

Page 10: ...onfirmed with short acoustic beep Default value Yes LED SYSTEM pulsing when card close to the reader When option is set then orange LED SYSTEM pulses whenever card is detected near the reader Default value No Battery low level signalisation When option is set then lock signals low battery level by orange LED SYSTEM indicator pulsing and series of 5 acoustic beeps after card reading Default value Y...

Page 11: ... value 0 Application ID The parameter Application ID AID is located in card s MAD sector and it specifies the sector where programmable card number PCN is stored if the Sector type see above is configured as MAD Default value 5156 Roger AID Block ID The parameter specifies the block number where programmable card number PCN is stored in a particular sector of card s memory For sectors 0 31 blocks ...

Page 12: ...installation make sure that door cylinder is long enough Lock installation Make holes in door using drilling template In case of non rebated door it might be necessary to use metal plate Both drilling template and metal plate are included in the factory new set Install mortise lock in such a way that marks which specify proper location of handle pin will be aligned fig 6 Lead K and L groups of wir...

Page 13: ... of the product This symbol placed on a product or packaging indicates that the product should not be disposed of with other wastes as this may have a negative impact on the environment and health The user is obliged to deliver equipment to the designated collection points of electric and electronic waste For detailed information on recycling contact your local authorities waste disposal company o...

Reviews: