background image

RWL-2 Operating Manual.doc 

 

2018-06-29 

 

5/17 

 

F

UNCTIONAL DESCRIPTION

 

The RWL-2 can be used as autonomous access control point, where the access is granted based on 

the data stored in the lock’s memory, or as a networked access point operating in the on-line access 
control system. In the 

Online mode

 access is controlled by the external controller. Transmission 

between the lock and controller is wireless and requires intermediary RWH-1 hub. Regardless of the 

selected working mode (online or offline) the lock requires configuration which can be done from the 
programming computer with the RogerVDM application and connected to the lock through RUD-1 

communication interface. If the lock is designated to operate in 

Offline mode

 with list of 50 users, 

each equipped with 

Main card

 and 

Backup card

, it can be programmed manually without computer. In 

this scenario, two programming cards, called ADD card and DEL card, are used to program the unit.  

Proximity cards 

The lock is equipped with a card reader which supports MIFARE® Ultralight/Classic/DESFire/Plus 
cards. Factory configured device reads card serial number (CSN - 

Chip Serial Number

), but using 

RogerVDM software it can be configured to use programmable card number (PCN – 

Programmable 

Card Number

) stored in the encrypted memory of the MIFARE card.  

Card number 

The card number which RWL-2 lock reads from the card and returns to the access controller is called 

RCN (

Returned Card Number

). In general, the RCN can be composed of two sections: 

·

 

CSN section 

·

 

PCN section 

The CSN section is a part of the RCN card number taken from the card serial number (CSN). The 
serial number is programmed by card manufacturer. 
The PCN section is a part of the RCN card number taken from the card’s programmable memory. The 
programmable number can be encrypted with own key in order to enable protection against card 

copying. 

Using RogerVDM program, installer can define the method used to read card number. It is possible to 
operate solely with CSN or PCN number, or combination of both (CSN+PCN). By default, lock utilizes 

CSN number. 

Note: Due to relatively easy copying of the card serial number (CSN), it is recommended to configure 
the lock for operation with programmable card number (PCN). If so, cards have to be programmed in 

the way which corresponds with lock’s card number configuration. 

Offline mode 

In the 

Offline mode

, the lock grants access for cards stored in its memory. The lock can operate 

permanently in 

Offline mode

 or enter this mode temporary, when operating in 

Online mode

 but 

wireless connection with controller is lost.  

Up to 100 cards can be defined and stored in lock’s memory. Each card can be authorised for 
momentary door opening (option: 

Normal access

) and/or to open the door for unlimited time (option: 

Office access

). If the card is authorized for 

Normal access

 then it opens the lock for the time specified 

by the parameter 

Lock pulse

. If the card is authorized for 

Office mode 

 then it can open the lock for 

unlimited time. When lock is switched to 

Office mode 

door can be open without use of a card. If the 

card is authorised for 

Normal access

 and 

Office mode

 then in order to get access it shall be used once 

while in order to activate 

Office mode 

it shall be used twice. 

Backup cards 

Up to 100 cards can be defined and stored in lock’s memory. Each card can belong to individual user. 
Optionally the lock can operate with 50 users only. In such a case each user can have two cards: 

Main 

card

 and 

Backup card

. Both cards have the same authorizations. Factory new lock is configured to 

Summary of Contents for RWL-2

Page 1: ...Roger Access Control System RWL 2 Wireless Lock Operating Manual Firmware version 1 0 Document version Rev C ...

Page 2: ...r can be always open without use of electronics The external handle is separated from the latch and moves freely When the access is granted the electronic module couples the external handle with latch to enable door opening The RWL 2 lock can be optionally equipped with door cylinder and then be opened from the outside with traditional metal key Optionally the RWL 2 can be equipped with external d...

Page 3: ...er A and hole for door cylinder which can be used for emergency door opening with mechanical key The electronic module which is located inside the escutcheon includes service contact B and programming contacts C Wires with plug E are used to connect the module with battery pack Three isolated wires F ended with heat shrinkable sleeve are used to connect external deadbolt and door contact The statu...

Page 4: ...o replace batteries remove hex screw and battery cover Wires with plug G are connected to socket E at external escutcheon in order to supply it Fig 5 RWL 2 exit escutcheon Door cylinder RWL 2 lock enables installation of a lock cylinder Such cylinder enables emergency door opening from the outside using metal key The size of cylinder depends on door thickness and it must be selected in such way th...

Page 5: ...ction is a part of the RCN card number taken from the card s programmable memory The programmable number can be encrypted with own key in order to enable protection against card copying Using RogerVDM program installer can define the method used to read card number It is possible to operate solely with CSN or PCN number or combination of both CSN PCN By default lock utilizes CSN number Note Due to...

Page 6: ...ock automatically switches to Offline mode and continues operation based on its internal configuration settings When the wireless connection is restored then the lock automatically returns to Online mode Radio channels The wireless communication utilizes the IEEE 802 15 4 2 4GHz band which is shared with Wi Fi networks If the lock uses the same channel as Wi Fi network then in case of intensive Wi...

Page 7: ...ec pulse when access is granted and external handle is coupled two 2 sec pulses when access is denied lights steadily when operates in Office mode LED SYSTEM Orange lights steadily in case of lock s configuration error pulses slowly in case of low battery level batteries must be replaced pulses every 2 sec when wireless connection is being established in Online mode Power supply RWL 2 lock is supp...

Page 8: ...DD card and DEL card The manual programming of the users can be used either when lock operates with Backup cards 50 users limit or without Backup cards 100 users limit When lock operates with 100 user limit programming steps related to the Backup cards shall be skipped Note It is possible to program new ADD and DEL programming cards during memory reset procedure User adding A Read ADD programming ...

Page 9: ...mode or Offline mode In case of Offline mode it is also possible to configure list of 100 users with Main cards instead of default list of 50 users with Main cards and Backup cards The selection of user limit is done with the parameter Backup cards When the option is set to 1 Yes then lock operates with 50 users limit Note It is recommended to backup RWL 2 settings save them to file and protect ag...

Page 10: ...ration Read from Device Reads configuration from device Send to Device Upload configuration to device Tab Credentials Add Adds new user Edit Edit existing user Delete Delete existing user Delete all Delete all users Read from file Read users list from file Write to file Save users list to file Read from device Read users list from device Send to device Save users list to device Tab Tools Erase RAC...

Page 11: ...n the option is off then each user can have the Main card only Default value Yes Card codes protection When option is set then it is not possible to read user card codes from the lock s memory Once option is set it can be cleared by memory reset procedure only The purpose of the option is to prevent unauthorized person to read card numbers from the lock s memory Default value No Online mode Wirele...

Page 12: ...nput which monitors deadbolt position if installed Default value Deadbolt DOOR CONTACT comment Any text to be displayed in VISO management software in order to facilitate object identification DOOR CONTACT object represents input which monitors door contact if installed Default value Door contact LED RED comment Any text to be displayed in VISO management software in order to facilitate object ide...

Page 13: ...d number PCN and the card serial number CSN When the option is disabled then the returned card number RCN is composed of the card serial number CSN only Default value None Format The format of the programmable card number PCN stored in the card s memory Default value BIN First byte position FBP The parameter specifies the position of the most significant byte MSB of programmable card number PCN De...

Page 14: ...SB of programmable card number PCN Default value 7 Sector ID The parameter specifies sector number in card s memory where programmable card number PCN is stored Default value 0 Application ID The parameter Application ID AID is located in card s MAD sector and it specifies the sector where programmable card number PCN is stored if the Sector type see above is configured as MAD Default value 5156 R...

Page 15: ... accompanies When user is granted with the Normal access authorisation it can open a door for the time defined by Lock pulse parameter When user is granted with Office mode it can open the door for unlimited time and then when required using the same card it can terminate Office mode Both options can be granted to the same user When card has both authorisations with the first card usage lock opens...

Page 16: ... of wires fig 3 Lead battery wires through hole and then connect them to the external escutcheon Check position of spindle support fig 7 and mount door handle spindle Install batteries 4xAAA in the pack and then insert into internal escutcheon Mount escutcheons and verify if the internal handle controls the cylinder and metal key can open the door Note Ensure access to metal key to enable emergenc...

Page 17: ...n 1 0 IX 2017 The first commercial version of the product This symbol placed on a product or packaging indicates that the product should not be disposed of with other wastes as this may have a negative impact on the environment and health The user is obliged to deliver equipment to the designated collection points of electric and electronic waste For detailed information on recycling contact your ...

Reviews: