RWL-2 Operating Manual.doc
2018-06-29
7/17
18
2,440
26
2,480
LED indicators
RWL-2 lock is equipped with 4 LED indicators which functions are described in the table below.
LED indicators
Name
Colour
Description
LED RED
Red
Online mode
: the function of this LED is programmed in VISO
management software.
Offline mode
: indicator is blinking when lock waits for the
optional second card reading. If it occurs, lock switches to
Office
mode
.
LED GREEN Green
In
Online mode
the function of this LED is programmed in VISO
management software.
In
Offline mode
the indicator is not used.
LED BLUE
Blue
Online mode
: the indicator is controlled by access controller in
accordance with the logic applied in the RACS 5 system.
If the lock switches to
Offline mode
due to communication
failure then LED BLUE is operated as lock was in
Offline mode
except that it blinks instead of steady light.
The indicator blinks slowly if wireless communication is not
configured.
In
Offline
mode
the indicator:
·
2 sec pulse when access is granted and external
handle is coupled
·
two 2 sec pulses when access is denied
·
lights steadily when operates in
Office mode
LED
SYSTEM
Orange
·
lights steadily in case of lock’s configuration error
·
pulses slowly in case of low battery level (batteries
must be replaced)
·
pulses every 2 sec when wireless connection is being
established in
Online mode
Power supply
RWL-2 lock is supplied from 4 pcs of AAA batteries. In case of average 10 operations daily the alkaline
batteries enable 1 year functioning. Low battery level is reported to VISO management software and
additionally it is signalled locally by orange LED SYSTEM pulsing and acoustic signal generated prior to
entering standby mode.
C
ONFIGURATION
RWL-2 lock can be programmed manually or from PC computer. Manual programming enables card
management for
Offline mode
only. All configuration settings can be setup and edited using
RogerVDM program. Connection to PC requires RUD-1 interface.
Factory new lock is configured for
Offline mode
and includes 2 programming cards (ADD card and DEL
card).
Lock pulse
by default is set to 2 sec while built-in RFID reader is configured to read card serial
numbers (CSN).