background image

Security Locks SL2000F and SL2000F-VP EN 

 

2020-05-06 

 

Page 

12

 of 

12

 

 

 

Product History 

Version  

Firmware 

Date 

Description 

SL2000F v1.0 

N/A 

11/2009 

Initial release of the product 

SL2000F-VP v1.0  N/A 

11/2009 

Initial release of the product 

SL2000F v2.0 

N/A 

05/2020 

Modifications of electronic components 

SL2000F-VP v2.0  N/A 

05/2020 

Modifications of electronic components 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact 

Roger sp. z o. o. sp. k. 

82-400 Sztum 

Gosciszewo 59 

Tel.:  +48 55 272 01 32 Fax: +48 55 272 01 33 

Technical support PSTN: +48 55 267 01 26  

e-mail

biuro@roger.pl

 

Web: 

www.roger.pl

 

The symbol of a crossed-through waste bin on wheels means that the product must be 
disposed of at a separate collection point. This also applies to the product and all 
accessories marked with this symbol. Products labelled as such must not be disposed of 
with normal household waste, but should be taken to a collection point for recycling 
electrical and electronic equipment. Recycling helps to reduce the consumption of raw 

materials, thus protecting the environment. 

Summary of Contents for SL2000F

Page 1: ...Electronic Code Lock SL2000F and SL2000F VP v2 0 Rev F ...

Page 2: ...oor operation SL2000F VP Three LEDs and buzzer Tamper 12VDC supply CE Introduction The SL2000F electronic code lock is dedicated to operate as a standalone door access control unit It is equipped with one relay output two transistor outputs and three inputs All codes and parameters programmed to device are stored in nonvolatile memory There are two version of SL2000F lock SL2000F plastic enclosure...

Page 3: ...n be used to control arming mode of the alarm zone or entire alarm system When the SL2000 is in Armed mode this output remains not active it become active when lock works in Disarmed mode The Status Output can be physically assigned to either Relay or OUT1 physical output for details see JP2 JP3 JP4 and JP5 settings The Status output can be used for rearming of an alarm zone or to control any othe...

Page 4: ... re enable access to the controlled door by switching the lock to the Disarmed mode The SL2000 can be switched between Armed and Disarmed modes via the MASTER code only Arming and Disarming In normal operation the SL2000 may work either in the Armed or Disarmed mode The actual status of the lock is presented on a dual color LED STATUS which lights up in red when lock is Armed and green when Disarm...

Page 5: ...ries of two beeps Normally pressing is used to mark the end of the code but when pressed separately for a time longer the 0 5s it triggers Door Bell indication Programming The USER Codes The SL2000 enables programming of up to 55 different USER codes The USER codes can be managed added deleted changed only in the Installer Programming mode to enter Installer Programming mode press INSTALLER Code O...

Page 6: ...from 00 to 99s default 04 C3C4 Specifies the time for which Door Lock output will be activated It can be programmed from 02 to 99s default 04 C5C6 Specifies the time within door must be closed otherwise Door Alarm will occur The C5C6 time is started from the moment when C4C4 time has passed by It can be programmed from 00 to 99s the 00 value sets unlimited time for door closing default 09 C7 Enabl...

Page 7: ... door 33 seconds Reprogramming of the MASTER code disabled Reprogramming of the INSTALLER code enabled Option 1 Timed Lock out off Option 2 Disable USER Codes When in Armed Mode off USER codes length 6 digits MASTER and INSTALLER codes length 10 digits Default Codes After the Memory Reset is accomplished Sl2000 restores following codes MASTER Code All digits are 1 1111 the length of the code depen...

Page 8: ... lock must be supplied form reliable power source calculate the adequate wire gauge to guarantee that the voltage on the SL2000 DC input will be 11 5V minimum Use separate pair of wires to supply door lock and SL2000 code lock Always add the silicon diode e g 1N4007 in parallel to the door lock note that diode must be located as close as possible to the door lock terminals It is forbidden to suppl...

Page 9: ...Security Locks SL2000F and SL2000F VP EN 2020 05 06 Page 9 of 12 ...

Page 10: ...Security Locks SL2000F and SL2000F VP EN 2020 05 06 Page 10 of 12 ...

Page 11: ...tion 12V 1 Red Supply input plus GND 2 Black Supply input minus TMP A 3 Grey Tamper contact A NC max 50mA 24V DC AC TMP B 4 Yellow Tamper contact B NC max 50mA 24V DC AC IN1 5 Blue Exit Button input NO type IN2 6 Red Blue Door Contact input NO type 1 5A 24V DC AC SYS 7 Pink LED SYSTEM input NO type OUT1 8 Green Transistor output max current sink 50mA 15V DC OUT2 9 Brown Transistor output max curre...

Page 12: ...ztum Gosciszewo 59 Tel 48 55 272 01 32 Fax 48 55 272 01 33 Technical support PSTN 48 55 267 01 26 e mail biuro roger pl Web www roger pl The symbol of a crossed through waste bin on wheels means that the product must be disposed of at a separate collection point This also applies to the product and all accessories marked with this symbol Products labelled as such must not be disposed of with norma...

Reviews: