background image

Security Lock SL2000H v1.0 EN Rev.C.doc   

2011-11-16 

 

 

 

Page 10 of 11

 

 
 

Connection assignments 

Label 

Description 

+12V 

Supply input plus 

GND 

Supply input minus 

TMP A 

Tamper contact A, NC max. 50mA/24V DC/AC 

TMP B 

Tamper contact B, NC max. 50mA/24V DC/AC 

IN1  

Exit Button input, NO type 

IN2 

Door Contact input, NO type, 1.5A/24V DC/AC 

SYS 

LED SYSTEM input, NO type 

OUT1 

Transistor output, max. current sink 50mA/15V DC   

OUT2 

Transistor output, max. current sink 50mA/15V DC   

REL1-COM 

REL1-NO 

REL1-NC 

REL1 output, 1.5A/24V DC/AC  

Technical Specification 

Parameter 

Value 

Supply 

10...15 VDC 

Current consumption 

Avg. 25 mA @ 12V DC, 
Max. 80 mA @ 15V DC with relay output active 

Anti-sabotage protection (Tamper) 

NC contact, 50mA/24V 

Environmental Class 
 

Class IV, outdoor-general, temp.: -25°C +60°C, 
relative humidity: 0 - 95% 

Dimensions 

160 X 90 X 45 mm 

Weight 

SL2000H: ~ 1300g 

Approvals 

CE 

Ordering Information 

Item 

Description 

SL2000H 

Vandal proof metal cover, access to the keypad protected by key-
locked doors, screw connection terminals, outdoor installation 
available 

Product History 

Version 

Firmware 

Date 

Description 

SL2000H v1.0 

N/A 

06/2011 

Initial release of the product 

 
 

Summary of Contents for SL2000H

Page 1: ...Roger Sp j Electronic Code Lock SL2000H v1 0 Document version Rev C ...

Page 2: ... be configured to operate in one of two modes Door Lock or Status The OUT2 has fixed function and is always assigned to signal Door Bell and Door Alarm states The REL1 output offers one switched NO NC contact rated 1 5A 30V AC DC The OUT1 and OUT2 lines are open collector transistor lines which normally remain in high resistance state however when triggered they short to supply minus The OUT1 2 tr...

Page 3: ...lock works in Disarmed mode The Status Output can be physically assigned to either Relay or OUT1 physical output for details see JP3 JP4 JP5 and JP6 settings The Status output can be used for rearming of an alarm zone or to control any other device or system which requires the ON OFF method of control This kind of operation is often called bistable or latch mode Either REL1 or OUT1 can be configur...

Page 4: ...yellow shorting this input with supply minus lights up LED SYSTEM The LED SYSTEM can be use to any arbitrary selected purpose required by the installer e g to indicate actual status of the alarm system or any other state Special options Option 1 Timed Lock Out If this option is enabled the Sl2000 disables the keypad for 60 seconds after three attempts of entry of the incorrect code After this time...

Page 5: ...00 between Armed and Disarmed modes it can be 4 10 digits long INSTALLER Code The INSTALLER code is required to enter the Installer Programming mode it can be 4 10 digits long USER Codes These codes are used solely to trigger the Door Lock momentary output Each time a valid USER code is entered the SL2000 starts counting C1C2 time delay and then activates Door Lock output for time defined by the C...

Page 6: ...aller Programming mode When the SL2000 accepts the new USER code it generates two series of two beeps Any attempt to program the USER code which already exists in the memory or to program it with a wrong length then will cause the programming error signaled by a long acoustic beep Configuring the SL2000 Memory Reset In order to configure the SL2000 you must perform the Memory Reset procedure and t...

Page 7: ... of the MASTER and INSTALLER codes enter 0 3 default 1 0 Both codes are 4 digits long 1 Both codes are 6 digits long 2 Both codes are 8 digits long 3 Both codes are 10 digits long If an illegal operation occur during Memory Reset the device will signal an error long beep and will return to the beginning of the programming so you can start to enter the C1 C10 digits once again The Memory Reset proc...

Page 8: ...vertical piece of supporting structure The SL2000H can be installed either indoor or outdoor location Assure that the surface beneath of the controller s rear panel is flat and smooth Disconnect power supply before making any electrical connections Once installed and electrically connected the unit has to be properly programmed When forgotten MASTER and INSTALLER codes can be restored to their def...

Page 9: ...Security Lock SL2000H v1 0 EN Rev C doc 2011 11 16 Page 9 of 11 ...

Page 10: ...REL1 NO REL1 NC REL1 output 1 5A 24V DC AC Technical Specification Parameter Value Supply 10 15 VDC Current consumption Avg 25 mA 12V DC Max 80 mA 15V DC with relay output active Anti sabotage protection Tamper NC contact 50mA 24V Environmental Class Class IV outdoor general temp 25 C 60 C relative humidity 0 95 Dimensions 160 X 90 X 45 mm Weight SL2000H 1300g Approvals CE Ordering Information Ite...

Page 11: ... crossed through waste bin on wheels means that the product must be disposed of at a separate collection point This also applies to the product and all accessories marked with this symbol Products labeled as such must not be disposed of with normal household waste but should be taken to a collection point for recycling electrical and electronic equipment Recycling helps to reduce the consumption o...

Reviews: