module contour (by at least 5mm at each side – see fig. 3). The installation of XM-2DR module 

must be executed in accordance with valid safety rules. 
 

 

Fig. 3 The arrangement of XM-2DR-BRD mounting holes 

3.

 

C

ONFIGURATION

 

3.1 Module address 

The configuration of XM-2DR expansion module is performed by means of jumpers in accordance 
with table 4. 

Table 4. Configuration jumpers 

Jumper 

Function 

JP1 

Address jumper „1” 

JP2 

Address jumper „2” 

JP3 

Address jumper „4” 

JP4 

Address jumper „8” 

JP5 

Unused 

JP6 

Unused 

JP7 

Selection of operation mode: Standalone/Normal 

FDM 

Firmware upgrade 

 

Summary of Contents for XM-2DR

Page 1: ...Roger Access Control System XM 2DR XM 2DR BRD I O Extension Module Operating Manual Firmware version 1 0 0 Hardware version 1 0 Document version Rev E ...

Page 2: ...equipped with plastic enclosure and is dedicated to installation on DIN 35mm rail while XM 2DR BRD is electronic module without any enclosure but it is accompanied with adapter for installation on DIN 35mm rail Table 1 Specification Parameter Description Supply voltage Nominal 12 VDC min max range 10 15VDC Current consumption 25mA both relays deactivated 110mA both relays activated Relay outputs R...

Page 3: ... Clock Data interface line DATA IN1 IN1 input line IN2 IN2 input line REL1 NO REL1 relay output contact normally opened COM REL1 relay output common terminal NC REL1 relay output contact normally closed REL2 NO REL2 relay output contact normally opened COM REL2 relay output common terminal NC REL2 relay output contact normally closed In the fig 2 there is shown connection diagram for XM 2DR and PR...

Page 4: ...en the module stops its operation deactivates both relays and signals the error by means of LED Power indicator blinks 10 times per second Note For proper communication by means of RACS Clock Data bus it is required to connect all GND terminals of devices Such requirement is satisfied if both devices are supplied from the same point as in fig 2 If devices are supplied from different power supply u...

Page 5: ...ngement of XM 2DR BRD mounting holes 3 CONFIGURATION 3 1 Module address The configuration of XM 2DR expansion module is performed by means of jumpers in accordance with table 4 Table 4 Configuration jumpers Jumper Function JP1 Address jumper 1 JP2 Address jumper 2 JP3 Address jumper 4 JP4 Address jumper 8 JP5 Unused JP6 Unused JP7 Selection of operation mode Standalone Normal FDM Firmware upgrade ...

Page 6: ...ger devices are always delivered with the latest version of firmware but it can be updated by customer The latest version of firmware which might offer new functionalities and or eliminate errors is available at www roger pl New firmware can be uploaded to XM 2DR by means of computer z with RogerISP software ver 5 or newer and it requires communication interface device e g RUD 1 connected to USB p...

Page 7: ...deliver equipment to the designated collection points of electric and electronic waste For detailed information on recycling contact your local authorities waste disposal company or point of purchase Separate collection and recycling of this type of waste contributes to the protection of the natural resources and is safe to health and the environment Weight of the equipment is specified in the doc...

Reviews: