XM-2DR Operating Manual.doc 

 

 

 

Page 

6

 of 

7

 

Note: Every time a jumper is put or removed it is necessary to restart the module in order to make 
new settings effective. The restart can be done by means of RESET button or power supply switch 

off and on. 

The address of XM-2DR can be programmed by means of jumpers based on their values e.g. 
jumpers on pins JP1 and JP3 signify the address ID=5 (1+4 = 5) while jumpers on all JP1…JP4 pins 

signify ID=15 (1+2+4+8 = 15).  
JP7 pins can be used for selection of operation mode. If the jumper is on JP7 then XM-2DR 
operates in standalone mode and then its relay outputs can be activated by electric signal at 

corresponding inputs i.e. IN1 -> REL1 and IN2 -> REL2. If there is no jumper on JP7 pins then XM-
2DR operates in normal mode and control of its outputs and inputs is performed by controller by 

means of RACS Clock & Data protocol. 

Note: In case of network operating mode i.e. communication with PR series controller, it is 
necessary to set XM-2DR address ID=5. 

3.2 Firmware update 

Roger devices are always delivered with the latest version of firmware but it can be updated by 
customer. The latest version of firmware, which might offer new functionalities and/or eliminate 

errors is available a

www.roger.pl

New firmware can be uploaded to XM-2DR by means of 

computer z with RogerISP software (ver. 5 or newer) and it requires communication interface 

device e.g. RUD-1 connected to USB port of the computer. 
 

Firmware update procedure  

·

 

Place jumper on FDM pins 

·

 

Connect XM-2DR to RUD-1 in accordance with table 5 

·

 

Reset the device (use RESET button or switch power supply off/on)  

·

 

Start RogerISP software and select communication port from the list 

·

 

In Firmware window select firmware *.hex file 

·

 

Click Program button 

·

 

After firmware upload, remove jumper from FDM pins and reset the device (use RESET button 
or switch power supply off/on) 

·

 

Disconnect XM-2DR from RUD-1 

Table 5. Connection of XM-2DR and RUD-1 

XM-2DR terminal 

RUD-1 terminal 

+12V 

GND 

IO1/CLK 

IO2/DTA 

 

4.

 

O

RDERING INFORMATION

 

Product 

Description 

XM-2DR 

Input/output addressable extension module with enclosure for installation on 
DIN 35mm rail 

XM-2DR-BRD 

Input/output addressable extension module as electronic module without 

enclosure 

 

Summary of Contents for XM-2DR

Page 1: ...Roger Access Control System XM 2DR XM 2DR BRD I O Extension Module Operating Manual Firmware version 1 0 0 Hardware version 1 0 Document version Rev E ...

Page 2: ...equipped with plastic enclosure and is dedicated to installation on DIN 35mm rail while XM 2DR BRD is electronic module without any enclosure but it is accompanied with adapter for installation on DIN 35mm rail Table 1 Specification Parameter Description Supply voltage Nominal 12 VDC min max range 10 15VDC Current consumption 25mA both relays deactivated 110mA both relays activated Relay outputs R...

Page 3: ... Clock Data interface line DATA IN1 IN1 input line IN2 IN2 input line REL1 NO REL1 relay output contact normally opened COM REL1 relay output common terminal NC REL1 relay output contact normally closed REL2 NO REL2 relay output contact normally opened COM REL2 relay output common terminal NC REL2 relay output contact normally closed In the fig 2 there is shown connection diagram for XM 2DR and PR...

Page 4: ...en the module stops its operation deactivates both relays and signals the error by means of LED Power indicator blinks 10 times per second Note For proper communication by means of RACS Clock Data bus it is required to connect all GND terminals of devices Such requirement is satisfied if both devices are supplied from the same point as in fig 2 If devices are supplied from different power supply u...

Page 5: ...ngement of XM 2DR BRD mounting holes 3 CONFIGURATION 3 1 Module address The configuration of XM 2DR expansion module is performed by means of jumpers in accordance with table 4 Table 4 Configuration jumpers Jumper Function JP1 Address jumper 1 JP2 Address jumper 2 JP3 Address jumper 4 JP4 Address jumper 8 JP5 Unused JP6 Unused JP7 Selection of operation mode Standalone Normal FDM Firmware upgrade ...

Page 6: ...ger devices are always delivered with the latest version of firmware but it can be updated by customer The latest version of firmware which might offer new functionalities and or eliminate errors is available at www roger pl New firmware can be uploaded to XM 2DR by means of computer z with RogerISP software ver 5 or newer and it requires communication interface device e g RUD 1 connected to USB p...

Page 7: ...deliver equipment to the designated collection points of electric and electronic waste For detailed information on recycling contact your local authorities waste disposal company or point of purchase Separate collection and recycling of this type of waste contributes to the protection of the natural resources and is safe to health and the environment Weight of the equipment is specified in the doc...

Reviews: