38.
6.4
Service Intervals
6.4.1
Daily Checks—Unit Running at Operating Conditions
1. Check lubricant level.
2. Check for existing alarms.
3. Check operating temperatures.
4. Check air-cooled cooler operation.
5. Observe capacity control system for proper operation (See Description of Operations / Display
and Control manual).
6. Check for lubricant or air leaks.
7. Check next service intervals.
8. Fill in daily record card (See Section 8.0).
6.4.2
When Required by Indicators and Gauges
1. Add lubricant.
2. Change filter elements (air, lubricant, separator.)
3. Perform any prescribed service intervals indicated by the controller.
6.4.3
Monthly
1. Test high temperature safety devices.
2. Mail daily record card to factory.
6.4.4
Every 1,000 Hours
1. Change lubricant filter element.
2. Change inlet air filter element.
3. Submit lubricant sample for testing.
4. Test high temperature trips.
6.4.5
Every 3,000 Hours
1. Perform 1,000 hour interval service items.
2. Change lubricant (earlier if indicated by a testing program).
3. Change separator elements.
4. Clean differential pilot valve, if equipped.
Summary of Contents for KI Series
Page 1: ...1 Model __________________ Serial __________________ Rotary Screw Air Compressors...
Page 8: ...7 INTENTIONALLY BLANK...
Page 9: ...8 CHAPTER 1 GENERAL INFORMATION...
Page 19: ...10 CHAPTER 2 INSTALLATION INSTRUCTIONS...
Page 26: ...17 CHAPTER 3 ELECTRICAL INFORMATION...
Page 30: ...21 CHAPTER 4 COMPRESSOR LUBRICANT...
Page 39: ...30 INTENTIONALLY BLANK...
Page 40: ...31 CHAPTER 5 AIR INLET FILTER INFORMATION...
Page 43: ...34 INTENTIONALLY BLANK...
Page 44: ...35 CHAPTER 6 COMPRESSOR OPERATIONS...
Page 49: ...40 INTENTIONALLY BLANK...
Page 50: ...41 CHAPTER 7 TROUBLESHOOTING...
Page 57: ...48 CHAPTER 8 FORMS RECORDS AND ELECTRICAL SCHEMATICS...
Page 58: ...49...
Page 59: ...50...
Page 60: ...51...
Page 61: ...52...
Page 62: ...53...
Page 63: ...54...
Page 64: ...55...
Page 65: ...56 INTENTIONALLY BLANK...
Page 66: ...57...