SMIQ
Digital Standard PHS
1125.5555.03
E-9
2.121
FREQ
100. 000 000 0
MHz
FREQUENCY
LEVEL
ANALOG MOD
VECTOR MOD
DIGITAL MOD
DIGITAL STD
LF OUTPUT
SWEEP
LIST
MEM SEQ
UTILITIES
PHS
PHS
IS-95
NADC
PDC
GSM
STATE
MODULATION...
TRIGGER MODE
EXECUTE TRIG
TRIGGER....
CLOCK...
POWER RAMP C>
SLOT ATTENUA
TRIGGER SOURCE
INT
EXT
EXT TRIGGER DELAY
0 Symb
EXT RETRIGGER INHIBIT
0 Symb
TRIGGER OUT2 DELAY
0 Symb
TRIGGER OUT2 PERIOD
1 Frames
LEVEL
- 30.0
dBm
PEP
- 27.5
dBm
SYNC
DN
1
2
Fig. 2-71
Menu DIGITAL STD - PHS_TRIGGER..., SMIQ equipped with Modulation Coder SMIQB20
and Data Generator SMIQB11
(TRIGGER...)
TRIGGER SOURCE
Selection of trigger source.
EXT
The PHS signal generation is started by
the active slope of an external trigger
signal.
The polarity, the trigger threshold and
the input resistance of the TRIGIN input
can be modified in menu
DIGITAL MOD - EXT INPUTS.
INT
A trigger event can be executed by
EXECUTE TRIGGER .
IEC/IEEE-bus
:SOUR:PHS:TRIG:SOUR EXT