Digital Standard PDC
SMIQ
1125.5555.03
2.290
E-9
RATE
CONFIGURATION...
Opens a window for determining which slots in the frame are to be configured
as half-rate and full-rate channels. Full-rate channels occupy two slots in a
frame, the second slot is fully determined by the configuration of the first slot.
The following eight combinations can be selected:
Selection
Full-rate slots
Half-rate slots
ALL HALF
keine
0, 1, 2, 3, 4, 5
FULL 1
0 + 3
1, 2, 4, 5
FULL 2
1 + 4
0, 2, 3, 5
FULL 3
2 + 5
0, 1, 3, 4
FULL 1+2
0 + 3 and 1 + 4
2, 5
FULL 1+3
0 + 3 and 2 + 5
1, 4
FULL 2+3
1 + 4 and 2 + 5
0, 3
ALL FULL
0 + 3 and 1 + 4 and 2 + 5
none
IEC/IEEE-bus command
SOUR:PDC:RCON AHAL
SELECT SLOT...
Selection of one of 6 possible slots. The number depends on the setting under
RATE CONFIGURATION. When selecting the slot, a window is opened in
which the data contents belonging to this slot can be defined. The content of
the window depends on whether an UPLINK or DOWNLINK was selected
under LINK DIRECTION. If the cursor is placed onto a slot in the diagram, it
may be switched on and off by pressing one of the unit keys (toggle function).
Menu selection:
BURST TYPE = TCH
FREQ
100. 000 000 0
MHz
FREQ UENCY
LEVE L
ANAL OG MOD
VECT OR MOD
DIGI TAL MO D
DIGI TAL ST D
LF OUTPUT
SWEE P
LIST
MEM SEQ
UTIL ITIES
PDC
PHS
IS95
NADC
PDC
GSM
SLOT
R
P
DATA
SYNC
CC
SF
SACCH
DATA
0 DN
4
2
112
20
8
1
21
112
BURST TYPE...
TCH
BURST STATE
OFF
ON
SET DEFAULT
SCRAMBLE STATE
OFF
ON
SCRAMBLE START
001 H
SUPER FRAME
OFF
ON
RCH POSITION
1
------------------BURST CONTENTS----------------
R
0 H
P
2 H
DATA
PN9
SYNC
8 7A4B H
SYNC2
3 1BAF H
C C
0 0 H
S F
0 H
SACCH
PN9
R CH
PN9
-------------------CHANGE DATA------------------
SELECT DATA LIST...
CURRENT: R&STDM
COPY CURRENT DATA LIST...
DELETE DATA LIST...
EDIT DATA LIST...
LEVEL
- 30.0
dBm
PEP
- 27.4
dBm
POWE
SLOT
SAVE
LINK
RATE
SELE
EDIT
0
TC
Fig. 2-191
Menu DIGITAL STD - PDC - SELECT SLOT, LINK DIRECTION DOWNLINK, SMIQ
equipped with Modulation Coder SMIQB20 and Data Generator SMIQB11