Remote-control commands
DVB-H
68
Operating Manual 1008.0970.12 ─ 16
[:SOURce<hw>]:BB:DVB:CLOCk:SYNChronization:EXECute
Performs automatically adjustment of the instrument's settings required for the syn-
chronization mode, set with the command
BB:DVB:CLOC:SYNC:MODE
.
Example:
BB:DVB:CLOC:SYNC:MODE MAST
the instrument is configured to work as a master one.
BB:DVB:CLOC:SYNC:EXEC
all synchronization's settings are adjusted accordingly.
Usage:
Event
Manual operation:
See
"Set Synchronization Settings"
[:SOURce<hw>]:BB:DVB:CLOCk:SYNChronization:MODE
<Mode>
Selects the synchronization mode.
This parameter is used to enable generation of very precise synchronous signal of sev-
eral connected R&S
SMBVs.
Note:
If several instruments are connected, the connecting cables from the master instru-
ment to the slave one and between each two consecutive slave instruments must have
the same length and type.
Avoid unnecessary cable length and branching points.
Parameters:
<Mode>
NONE | MASTer | SLAVe
NONE
The instrument is working in stand-alone mode.
MASTer
The instrument provides all connected instrument with its syn-
chronisation (including the trigger signal) and reference clock
signal.
SLAVe
The instrument receives the synchronisation and reference clock
signal from another instrument working in a master mode.
*RST:
NONE
Example:
BB:DVB:CLOC:SYNC:MODE MAST
the instrument is configured to work as a master one.
Manual operation:
See
4.2 System Configuration
This subsystem contains commands regarding the system configuration of the DVB
signal.