Remote-control commands
DVB-H
67
Operating Manual 1008.0970.12 ─ 16
Parameters:
<Multiplier>
integer
Range:
1 to 64
Increment: 1
*RST:
4
Example:
SOURce1:BB:DVB:CLOCk:SOURce EXTernal
selects the external clock source.
SOURce1:BB:DVB:CLOCk:MODE MSAMple
selects clock type "Multiple Sample", i.e. the supplied clock has
a rate which is a multiple of the sample rate.
SOURce1:BB:DVB:CLOC:MULTiplier 12
the multiplier for the external clock rate is 12.
Manual operation:
See
[:SOURce<hw>]:BB:DVB:CLOCk:SOURce
<Source>
The command selects the clock source.
For two-path instruments, selecting
EXTernal
is only possible for path A, since the
external clock source is permanently allocated to path A. Selection
AINternal
is only
possible for path B.
Parameters:
<Source>
INTernal | EXTernal | AINTernal
INTernal
The internal clock reference is used.
EXTernal
The external clock reference is supplied to the CLOCK connec-
tor. Commands
:BB:DVB:CLOCk:MODE
and
:MULTiplier
are
used to enter the type of the external clock.
AINTernal
The clock source of path A is used for path B.
*RST:
INTernal
Example:
BB:DVB:CLOC:SOUR EXT
selects the external clock source. The clock is supplied via the
CLOCK connector.
BB:DVB:CLOC:MODE MSAM
selects clock type "Multiple Sample", i.e. the supplied clock has
a rate which is a multiple of the sample rate.
BB:DVB:CLOC:MULT 12
the multiplier for the external clock rate is 12.
Manual operation:
See
General Commands
Summary of Contents for 1402.9557.02
Page 8: ...Preface DVB H 8 Operating Manual 1008 0970 12 16 Conventions Used in the Documentation ...
Page 44: ...DVB H User Interface DVB H 44 Operating Manual 1008 0970 12 16 Trigger Marker Clock Settings ...
Page 76: ...Remote control commands DVB H 76 Operating Manual 1008 0970 12 16 TPS Settings ...