Remote Control Commands
R&S
®
NGP800
129
User Manual 5601.5610.02 ─ 04
Example:
FUSE:TRIP:CLE? (@1)
Queries OCP reset state at channel 1.
Example:
See
Usage:
Setting only
FUSE:DELay:INITial
<New value for voltage>[, <Channel list>]
FUSE:DELay:INITial?
[<Channel list>]
Sets the initial fuse delay time once output turns on.
Parameters:
<duration>
<numeric value> | MIN | MINimum | MAX | MAXimum
<numeric value>
Numeric value for initial fuse delay.
MIN | MINimum
Min value for initial fuse delay.
MAX | MAXimum
Max value for initial fuse delay.
Range:
0.00 to 60.00
*RST:
0
Default unit: s
Parameters for setting and query:
<Channel list>
<list>
Example:
FUSE:DEL:INIT? (@1)
Queries initial fuse delay time at channel 1.
Example:
See
FUSE:DELay[:BLOWing]
<New value for voltage>[, <Channel list>]
FUSE:DELay[:BLOWing]?
[<Channel list>]
Sets the fuse delay time.
Parameters:
<duration>
<numeric value> | MIN | MINimum | MAX | MAXimum
<numeric value>
Numeric value for the initial fuse delay.
MIN | MINimum
Min value for initial fuse delay.
MAX | MAXimum
Max value for initial fuse delay.
Range:
0.00 to 10.00
*RST:
0
Default unit: s
Parameters for setting and query:
<Channel list>
<list>
Configuration Commands
www.allice.de