Remote Control Commands
R&S
®
NGP800
161
User Manual 5601.5610.02 ─ 04
Example:
DATA:POIN?
"/USB1A/NGP/logging/log-20201203T101025.829.csv"
-> 5
Returns 5 log files counts from "/USB1A/NGP/logging/
log-20201203T101025.829.csv".
Usage:
Query only
HCOPy:DATA?
Returns the actual display content (screenshot).
Usage:
Query only
HCOPy:SIZE:X?
Returns the horizontal dimension of the screenshots.
Usage:
Query only
HCOPy:SIZE:Y?
Returns the vertical dimension of the screenshots.
Usage:
Query only
LOG[:STATe]
<arg0>
Sets or queries the data logging state.
Parameters:
<state>
1
Data logging function is enabled.
0
Data logging function is disabled.
*RST:
0
Example:
LOG ON
LOG?
-> 1
Data logging function is activated.
LOG:COUNt
<Set new value>[, <Return min or max>]
LOG:COUNt?
[<Return min or max>]
Sets or queries the number of measurement values to be captured.
Setting parameters:
<count>
<numeric value> | MIN | MINimum | MAX | MAXimum
Data and File Management Commands
www.allice.de
Allice Messtechnik GmbH