Remote Control Commands
R&S
®
NGP800
119
User Manual 5601.5610.02 ─ 04
[SOURce:]VOLTage[:LEVel][:IMMediate]:STEP[:INCRement]
<desired stepsize>[,
<Optional default step query>]
[SOURce:]VOLTage[:LEVel][:IMMediate]:STEP[:INCRement]?
[<Optional default
step query>]
Sets or queries the incremental step size for the
command.
Setting parameters:
<stepsize>
<numeric value> | DEF | DEFault
<numeric value>
Step value in V.
DEF | DEFault
Default value of stepsize.
Range:
0.001 to 5.000
Increment: 0.001
*RST:
0.100
Default unit: V
Parameters for setting and query:
<stepsize>
DEF | DEFault
Queries the default voltage step size.
Example:
INST OUT1
VOLT:STEP 0.001
VOLT:STEP DEF
VOLT:STEP? DEF
-> 0.10
Returns the default stepsize voltage.
See also
Example "Configuring the output voltage"
7.5.5
Current Setting
The
SOURce:CURRent
subsystem contains the commands for setting the current limit
of the output channels. The default unit is A.
Configuration Commands