Remote Control Commands
R&S
®
NGP800
137
User Manual 5601.5610.02 ─ 04
Parameters for setting and query:
<Channel list>
<list>
Example:
POW:PROT:LEV? (@1)
Queries OPP value at channel 1.
Example:
See
Example "Configuring the overpower protection"
[SOURce:]POWer:PROTection:TRIPped?
[<Channel list>]
[SOURce:]POWer:PROTection:TRIPped??
[<Channel list>]
Queries the OPP state of the selected channel.
Parameters:
<Channel list>
<list>
Example:
POW:PROT:TRIP?
Response 1, the OPP is tripped.
Response 0, the OPP is not tripped.
Example:
POW:PROT:TRIP? (@1)
Queries OPP state at channel 1.
Usage:
Query only
See
Example "Configuring the overpower protection"
7.5.11
Reset Protection Tripped State
The
Protection
subsystem contains the command to reset the protection tripped
state.
[SOURce:]PROTection:CLEar
[<Channel list>]
Reset protection tripped state.
Parameters:
<Channel list>
<list>
Example:
PROT:CLE (@1)
Reset protection tripped state at channel 1.
Usage:
Setting only
7.5.12
Tracking Setting
The
TRACking
subsystem contains the commands for changes made on reference
channel are applied to the tracked channels.
...............................................................................138
.......................................................................................... 138
TRACking[:ENABle]:SELect:CH<CHANNEL>
................................................................... 138
Configuration Commands
www.allice.de
Allice Messtechnik GmbH