Remote Control Commands
R&S
®
NGP800
139
User Manual 5601.5610.02 ─ 04
TMC
USB TMC connection.
7.6
Measurement Commands
The
MEASure
subsystem provides commands to query the voltage and current values
of a channel.
......................................................................................... 139
.................................................................................139
.................................................................................140
MEASure[:SCALar]:STATistic:COUNt?
............................................................................. 140
MEASure[:SCALar]:STATistic:RESet
................................................................................140
MEASure[:SCALar]:CURRent[:DC]?
................................................................................ 141
MEASure[:SCALar]:CURRent[:DC]:AVG?
.........................................................................141
MEASure[:SCALar]:CURRent[:DC]:MAX?
........................................................................ 141
MEASure[:SCALar]:CURRent[:DC]:MIN?
..........................................................................141
MEASure[:SCALar]:CURRent[:DC]:STATistic?
.................................................................. 142
........................................................................................... 142
....................................................................................142
................................................................................... 142
.................................................................................... 143
MEASure[:SCALar]:POWer:STATistic?
.............................................................................143
MEASure[:SCALar][:VOLTage][:DC]?
............................................................................... 143
MEASure[:SCALar][:VOLTage][:DC]:AVG?
........................................................................143
MEASure[:SCALar][:VOLTage][:DC]:MAX?
....................................................................... 144
MEASure[:SCALar][:VOLTage][:DC]:MIN?
........................................................................ 144
MEASure[:SCALar][:VOLTage][:DC]:STATistic?
................................................................. 144
MEASure[:SCALar]:ENERgy?
[<Channel list>]
MEASure[:SCALar]:ENERgy??
[<Channel list>]
Queries the measured the current released energy value of the previous selected
channel.
Parameters:
<Channel list>
<list>
Example:
MEAS:ENER?
-> 5.382E+00 (value in Wh)
Example:
MEAS:ENER? (@1)
Queries the measured accumulated energy value at channel 1.
Usage:
Query only
MEASure[:SCALar]:ENERgy:RESet
[<Channel list>]
MEASure[:SCALar]:ENERgy:RESet
[<Channel list>]
Resets the energy counter for the selected channel.
Measurement Commands
www.allice.de
Allice Messtechnik GmbH