General information concerning the CE marking
General information
concerning the
CE marking
General Information Regarding the CE Marking
ROHDE & SCHWARZ measuring instruments comply with
regulations of the EMC Directive. ROHDE & SCHWARZ is
basing the conformity assessment on prevailing generic
and product standards. In cases with potentially different
thresholds, ROHDE & SCHWARZ instruments apply more
rigorous test conditions. Thresholds for business and com-
mercial sectors as well as small business are applicable
for interference emission (class 1B). As to the interference
immunity, the standard thresholds for the industrial sec-
tor apply. Measurement and data lines connected to the
measuring instrument significantly affect compliance with
specified thresholds. Depending on the respective appli
-
cation, utilized lines may differ. In regards to interference
emission and immunity during measurements, it is critical
that the following terms and conditions are observed:
1. Data Cables
It is imperative to only use properly shielded cables when
connecting measuring instruments and interfaces to ex-
ternal devices (printers, computers, etc.). Unless the man-
ual prescribes an even shorter maximum cable length,
data cables (input/output, signal/control) may not exceed
a length of 3m and may not be used outside of buildings.
If the instrument interface includes multiple ports for inter-
face cables, only one cable at a time may be connected.
Generally, interconnections require double-shielded con-
necting cables. The double-shielded cable HZ72 (available
at ROHDE & SCHWARZ) is well suitable as IEEE bus cable.
2. Signal Cables
In general, measuring cables for the transmission of sig-
nals between measuring point and measuring instrument
should be kept as short as possible. Unless the manual
prescribes an even shorter maximum cable length, sig-
nal cables (input/output, signal/control) may not exceed a
length of 1m and may not be used outside of buil-dings.
In general, all signal cables must be used as shielded con-
ductors (coaxial cable- RG58/U). It is important to ensure
proper ground connection. Signal generators require the
use of double-shielded coaxial cables (RG223/U, RG214/U).
3. Impact on Instruments
If strong high-frequency electric and magnetic fields are
present, it may occur despite diligent measurement setup
that unwanted signal units are injected into the instru-
ment via connected cables and lines. This does not result
in destruction or shutdown of ROHDE & SCHWARZ instru-
ments. In individual cases, external circumstances may
cause minor variations in the display and measuring values
beyond the selected specifications.
DECLARATION OF CONFORMITY
HAMEG Instruments GmbH
Industriestraße 6 · D-63533 Mainhausen
The HAMEG Instruments GmbH herewith declares conformity of the
product:
Product name
:
Arbitrary Power Supply
Type
:
HM8143
with
: HO820
Option
: HO880
complies with the provisions of the Directive of the Council of the
European Union on the approximation of the laws of the Member States
❙
relating to electrical equipment for use within defined voltage limits
(2006/95/EC) [LVD]
❙
relating to electromagnetic compatibility (2004/108/EC) [EMCD]
❙
relating to restriction of the use of hazardous substances in electrical
and electronic equipment (2011/65/EC) [RoHS].
Conformity with LVD and EMCD is proven by compliance with the
following standards:
EN 61010-1: 04/2015
EN 61326-1: 07/2013
EN 55011: 11/2014
EN 61000-4-2: 12/2009
EN 61000-4-3: 04/2011
EN 61000-4-4: 04/2013
EN 61000-4-5: 03/2015
EN 61000-4-6: 08/2014
EN 61000-4-11: 02/2005
For the assessment of electromagnetic compatibility, the limits of
radio interference for Class B equipment as well as the immunity to
interference for operation in industry have been used as a basis.
Date
: 8.6.2015
Signature
:
Holger Asmussen
General Manager