Remote Control Commands
R&S
®
NGA100
105
User Manual 5601.8919.02 ─ 03
TRIGger:OUT:CONDition:DIO<IO>
<arg0>
This command sets the trigger condition of the trigger output of the specified Digital I/O
line.
The line triggers when the output of the specified control source is turned off or on
Suffix:
<IO>
.
1..4
Parameters:
<arg0>
ON | OFF | FUSetrip | CCMode | VOLTlevel | CURRlevel | CRI-
Tevent | ARBitrary
ON
Trigger output is turned on.
OFF
Trigger output is turned off.
FUSetrip
Trigger output is linked to fuse tripped event.
VOLTlevel
Trigger output is linked to a set voltage level event.
CURRlevel
Trigger output is linked to a set current level event.
CRITevent
Trigger output is linked to a critical triggered event.
ARBitrary
Trigger output is linked to a EasyArb event.
*RST:
ON
TRIGger:OUT:CRITevent:DIO<IO>
<arg0>
This command sets or queries the critical event of the trigger output of the specified
Digital I/O line.
Suffix:
<IO>
.
1..4
Parameters:
<arg0>
OVP | OPP | OTP
OVP
Trigger output is linked to the OVP event
OPP
Trigger output is linked to the OPP event
OTP
Trigger output is linked to the OTP event
*RST:
OVP
Advanced Operating Commands