Operating Basics
R&S
®
NGA100
37
User Manual 5601.8919.02 ─ 03
Figure 5-6: Virtual keyboard
Invoke the on-screen keyboard as follows:
1. Move the cursor to the desired input field.
2. Press [Enter] key. The on-screen keyboard appears.
3. Once on the keyboard screen, press the arrow keys or turn the rotary knob to go to
the desired character.
4. Press the rotary knob to select the character.
Select
key if you want to create a space between characters.
To delete the last entered character, select the
key.
To delete the current entry, select the
key.
Select the
key to alternate between capital and small capital letters.
5. Repeat step 3 and 4 until all the characters are entered.
6. Select "OK" to confirm the input and exit the screen.
Select "ESC" or press [Menu] key to exit the screen without saving the changes.
5.4
Power Derating
The R&S NGA100 power supply series provides a maximum output power of 40 W for
a single channel model. Depending on the power supply models, up to 80 W of output
power is provided for models with two identical channels with a continuous voltage
range of 0 V to 35 V or 0 V to 100 V.
Combination of the set voltage and current limit results in the following output perfor-
mance graph.
Power Derating