Power Supply NGMO
Operation
4-10
4.00 / 07-2004
NOTE:
If you are in the Menu mode and you have selected a function
that accepts numerical entries, the direct numerical input mode
can be activated by pressing the
SHIFT
key without first pres-
sing the
ENTER
key. However, it is also possible to first select
the variation knob entry mode by pressing the
ENTER
key and
then entering the direct numerical entry mode by pressing the
SHIFT
key.
4.2.3.3
How to Change Settings in Menu Mode?
Most NGMO2 settings can only be changed inside the Menu mode. To
enter the Menu mode, press the MENU key once. A brief message is
displayed how to navigate through the menu. The NGMO2 then dis-
plays “A01.” or “B01.“(after power-on) or when you re-enter the Menu
mode, the last menu item that was previously selected. Now, a menu
item can be selected by turning the variation knob. The action to chan-
ge an item value or setting depends on the kind of item. If an item type
has predefined options, just press the left arrow key to move the square
brackets around a value one to the left and the right arrow key to move
it one to the right. The new selected setting comes into effect immedi-
ately. The ENTER key does not need to be pressed.
Items that accept numerical values are changed by using the variation
knob or the direct numerical input as described above. To enter one of
these modification modes either the ENTER key (for variation knob
entry) or the shift key must be pressed. To leave the entry mode just
press the ENTER key, which brings you back to the menu item selecti-
on mode.
NOTE:
Please note that the presence of absence of the cursor tells you
what the current entry mode is. If no cursor is displayed, you are
in menu item selection mode; if the underscore cursor is
displayed, you are in the variation knob entry mode and if a
flashing, solid cursor is displayed, the direct numerical entry
mode has been selected.
Summary of Contents for NGMO1
Page 8: ...Power Supply NGMO Tables 4 Version 4 00 07 2004 ...
Page 14: ...Power Supply NGMO Safety 2 2 4 00 07 2004 ...
Page 51: ...Operation Power Supply NGMO 4 00 07 2004 4 29 Fig 4 7 Status model structure ...
Page 52: ...Power Supply NGMO Operation 4 30 4 00 07 2004 ...
Page 84: ...Power Supply NGMO Ordering Information 6 2 4 00 07 2004 ...