Power Supply NGMO
Operation
4-16
4.00 / 07-2004
A/B25:
Relay 1
[on] off
Turns the output driver for relay 1 on or off. The driver
signal is applied to the “Control I/O” connector, Pin 1 on
the rear panel (ground on pin 8 and 9).
A/B26:
Relay 2
[on] off
Turns the output driver for relay 2 on or off. The driver
signal is applied to the “Control I/O” connector, Pin 2 on
the rear panel (ground on pin 8 and 9).
A/B27:
Relay 3
[on] off
Turns the output driver for relay 3 on or off. The driver
signal is applied to the “Control I/O” connector, Pin 3 on
the rear panel (ground on pin 8 and 9).
A/B28:
Relay 4
[on] off
Turns the output driver for relay 4 on or off. The driver
signal is applied to the “Control I/O” connector, Pin 4 on
the rear panel (ground on pin 8 and 9).
A/B29:
Recall setting
when power on (0-10)
The NGMO2 saves sets of settings in an internal
EEPROM. With the menu item “Recall settings when
power on” a user can select, which of the stored settings
are loaded when the device is powered up.
0: use factory defaults after power up
1 to 9: use user-defined settings, that have been previously
stored with the “SAVE” function 1 to 9.
10: use the last manual settings as the new power up
settings.
A/B30:
IEEE Address
(1-30)
This setting specifies the IEEE address of the NGMO2.
This setting is independent of the setting made with menu
item 29 (Recall setting, when power on).
Summary of Contents for NGMO1
Page 8: ...Power Supply NGMO Tables 4 Version 4 00 07 2004 ...
Page 14: ...Power Supply NGMO Safety 2 2 4 00 07 2004 ...
Page 51: ...Operation Power Supply NGMO 4 00 07 2004 4 29 Fig 4 7 Status model structure ...
Page 52: ...Power Supply NGMO Operation 4 30 4 00 07 2004 ...
Page 84: ...Power Supply NGMO Ordering Information 6 2 4 00 07 2004 ...